How it works
EER (energy efficiency ratio) is BTU/h of cooling per watt. SEER, used on US labels, is a seasonal figure that's usually higher than EER; for sizing batteries, use the EER or the running watts on the label. COP = EER ÷ 3.412.
Typical units
| Unit | Running watts | Start-up surge |
|---|---|---|
| 5,000 BTU window unit | 400–500 W | 1,200–1,500 W |
| 9,000–12,000 BTU inverter mini-split | 600–1,000 W | Gentle start |
| 13,500 BTU RV roof unit | 1,200–1,600 W | 3,000–4,000 W (≈1,600–2,000 W with soft-starter) |
| 15,000 BTU RV roof unit | 1,500–1,800 W | 4,000+ W |
| Portable 10,000 BTU | 900–1,200 W | 2,500–3,000 W |
Making it work off-grid
- A soft-starter or an inverter-compressor unit is the single biggest improvement.
- Insulation, shade and reflective window covers cut the cooling needed more than any electrical change.
- Running AC all night typically needs 3–8 kWh of battery: 24 V or 48 V systems and LiFePO4 batteries make this practical.
- See the generator size calculator and inverter size calculator.
Frequently asked questions
Can solar panels run an air conditioner?
Yes, during the day with enough panels and an inverter that handles the start-up surge. A 9,000 BTU unit drawing 900 W for 8 hours at 60% duty needs about 1.6 kW of panels in 5 peak sun hours, plus battery for evenings.
How many watts does an RV air conditioner use?
A 13,500 BTU roof unit draws about 1,200–1,600 W running and needs 3,000–4,000 W to start, unless it has a soft-starter.
What size generator runs a 13,500 BTU RV air conditioner?
Typically 3,000–3,500 W without a soft-starter, or a 2,000–2,200 W inverter generator with one.