Home › Inverters, loads & power

Generator fuel consumption calculator

Generators use fuel less efficiently at light loads. Enter the generator's rating, your typical load and fuel type to estimate fuel use and run time.

kW
kW
Litres for petrol or diesel; kg for propane.

Results

Fuel per hour—
Run time per tank—
Per hour (US gallons / lb)—
Fuel per kWh produced—

How it's estimated

Fuel per hour ≈ Rated kW × Fuel rate × (0.25 + 0.75 × Load fraction)

Fuel rates at full load are typical values: about 0.5 L/kWh for petrol, 0.33 L/kWh for diesel and 0.4 kg/kWh for propane. The (0.25 + 0.75 × load) term reflects the fact that a generator still burns about a quarter of its full-load fuel just turning over. Inverter generators in eco mode do better than this at light loads; open-frame builders' generators often do worse.

Worked example

A 3 kW petrol generator running a 1 kW load: 3 × 0.5 × (0.25 + 0.25) = 0.75 L/h. A 10 L tank lasts about 13 hours. Check the manufacturer's quoted run time at 25% and 50% load for your model.

Charging batteries with a generator

Battery charging is a good use of generator time because the charger can load the generator well. A bigger charger finishing in 2 hours burns less fuel than a small charger running for 6.

Frequently asked questions

How much fuel does a 2000W generator use per hour?

Typically 0.3–1.0 L (0.1–0.25 US gal) per hour, depending on load. Most quote 8–10 hours on about 4 L at 25% load in eco mode.

Does a generator use less fuel at lower load?

Yes, but not proportionally. At quarter load it uses roughly 40–50% of its full-load fuel.

Related calculators

More in Inverters, loads & power · all calculators