Solar panel voltage rises as temperature falls. On a frosty morning, a string that looks safe on paper can exceed your MPPT controller's maximum voltage and damage it.

V
V
%/°C
On the datasheet, usually −0.25 to −0.35 %/°C. If given in mV/°C, divide by Voc × 10.
The coldest air temperature you expect at sunrise.
V
For example the '100' in a 100/30 controller.

Results

String Voc at lowest temperature—
Cold Voc per panel—
Headroom to controller limit—
String Vmp (25 °C)—

The formula

Cold Voc per panel = Voc × (1 + coefficient ÷ 100 × (Tmin − 25)) String Voc = Cold Voc per panel × Panels in series

The coefficient is negative, and Tmin is below 25 °C, so the result is higher than the label Voc.

Worked example

Three 100 W panels with Voc 22.5 V and a coefficient of −0.29 %/°C, at −10 °C: 22.5 × (1 + −0.0029 × −35) = 24.8 V per panel, or 74.4 V for the string. That's safely inside a 100 V controller. Five of the same panels would reach 124 V and could destroy it.

The low-voltage side

An MPPT controller usually needs the panel voltage to be at least 5 V above the battery voltage to start charging, and panels lose voltage when hot. Victron, for example, quotes battery voltage + 5 V to start. Keep the string's Vmp comfortably above that in summer heat.

Tips

Frequently asked questions

How many solar panels in series on a 100V MPPT?

With typical 12 V-style panels (Voc around 22 V), three in series is safe in most UK and US climates. With 60-cell panels (Voc around 40 V) only two.

What happens if Voc exceeds the controller rating?

The controller can be permanently damaged, and it's not usually covered by warranty. Always check with the coldest expected temperature.