How the size is worked out
The calculator also uses a floor of about 35 litres of stored water per person, a common UK rule of thumb, and rounds up to a common cylinder size.
Typical sizes
| Household | UK cylinder | US tank water heater | Australian storage tank |
|---|---|---|---|
| 1–2 people, one shower | 120–150 L | 30–40 gal | 125–160 L |
| 3–4 people, one bathroom | 170–210 L | 40–50 gal | 250 L |
| 4–5 people, two bathrooms | 210–250 L | 50–60 gal | 315 L |
| 5+ people, three bathrooms | 250–300 L+ | 65–80 gal or a tankless unit | 400 L |
Heat pump cylinders are sized larger, because they store water cooler and reheat slowly. Solar thermal cylinders are often 1.5–2 times normal size to store the day's heat.
Cold water storage tanks (UK)
- Gravity (vented) systems have a cold water storage cistern, usually in the loft, that feeds the hot water cylinder and often the bath and shower taps.
- BS 6700 guidance suggests about 100–150 L for cold outlets only, 200–300 L where it also feeds the hot water, and around 100 L per bedroom in larger homes. 230 L is a common size.
- The Water Supply (Water Fittings) Regulations require a tight-fitting lid, an insect screen on the overflow and vent, insulation, and a warning overflow. See WRAS guidance.
- Unvented cylinders run at mains pressure and need no cold tank, but must be fitted by a qualified installer (Building Regulations Part G3 in England and Wales).
US: first-hour rating
US water heaters are compared by their first-hour rating (FHR) on the label: how many gallons of hot water they deliver in an hour starting full. Choose an FHR at least equal to the "busiest hour" figure above, converted to gallons.
For the energy to heat water, see the water heating calculator. For tanks and rainwater, see the off-grid water guide.
Frequently asked questions
What size hot water cylinder do I need for 4 people?
Usually about 170–210 litres for one bathroom, or 210–250 litres with two bathrooms where showers run back to back.
How big should a cold water tank be?
In the UK, around 230 litres is common where the tank feeds the hot water cylinder. BS 6700 guidance suggests 200–300 litres for hot and cold, or about 100 litres per bedroom in larger homes.
How long does a hot water cylinder take to heat up?
A 200 litre cylinder heated from 10 °C to 60 °C by a 3 kW immersion takes about 3 hours 50 minutes. A gas boiler coil does it in under an hour.
What size water heater do I need for a family of four in the US?
Typically a 40–50 gallon tank with a first-hour rating of 60–70 gallons, or a tankless heater sized for two showers at once.