Home › Guides › Off-grid water

Off-grid water: rainwater, pumps, treatment and the rules

How to collect, store, pump and treat water for a cabin, van or off-grid home: how much you need, rainwater harvesting, tanks, filtration and UV disinfection, pumps and their power use, freeze protection, greywater, emergency water at home, and the rules in the UK, USA and Australia, including US rainwater limits.

By Michael Johnson · Updated 16 November 2026 · How we check our guides

Water is the one thing you can't go without for more than a few days, and an off-grid property, a van or a home in a long outage needs its own supply. This guide covers collecting rainwater, sizing tanks, pumps and pressure, filtering and disinfecting water to drink, keeping pipes from freezing, and the rules in the UK, USA and Australia.

Treat all untreated water as unsafe to drink. Rainwater, wells, springs and streams can carry bacteria, viruses and parasites, and sometimes lead or chemicals. Use the treatment steps in section 5, and test any supply you rely on.
Related: see solar water pumping and ram pumps.

1. How much water you need

UseTypical per person per day
Drinking only (survival)3 litres (UK guidance) to 1 US gallon / 3.8 L (Ready.gov); more in heat
Drinking, cooking and basic washing10–20 L
Careful off-grid living (short showers, low-flush toilet)40–80 L
Typical mains-connected homeUK about 140 L; US about 300 L (80 gal); Australia about 150–200 L

Size your storage with the water tank calculator.

2. Sources: rain, wells, springs and surface water

SourceProsRisks
Rainwater from a roofSoft, free, usually low in chemicalsBird and animal droppings, dust, leaves; lead from old roofs and flashings; unreliable in dry spells
Bore or well (groundwater)Reliable, often good qualityNitrates, arsenic, iron, manganese, bacteria from septic tanks or livestock; needs a pump
SpringCan flow by gravitySurface contamination after rain; must be protected at the source
Stream, river, lake or damLarge volumesAlways contaminated with microbes; possible farm and industrial chemicals; algal toxins in warm weather

3. Rainwater harvesting

Litres collected ≈ roof area (m²) × rainfall (mm) × 0.8
(US: gallons ≈ roof area (ft²) × rainfall (inches) × 0.62 × 0.8)

4. Tanks: size, material and placement

5. Treating water to drink

Rainwater to drinking water: a typical treatment train Each stage removes something different. Non-drinking uses can skip the last stages; drinking water needs all of them. Roof (no lead flashing, treated timber or old lead paint) gutter + leaf guard First flush diverter 20–25 L TANK opaque, food-grade, sealed, screened calmed inlet floating extraction overflow + insect screen (1 mm mesh) Mains top-up only via an air gap (backflow) Pump + pressure tank Sediment 5–50 µm Carbon taste, chemicals UV lamp kills germs → drinking tap (test water before relying on it) Non-drinking uses toilets, washing, garden: pumped, sediment filter only
A typical rainwater treatment train. Wells and surface water may need extra steps for specific chemicals; test first.
MethodRemovesDoesn't removeNotes
BoilingBacteria, viruses, protozoaChemicals, lead, sedimentBring to a rolling boil. US CDC: boil for 1 minute (3 minutes above 2,000 m / 6,500 ft). An automatic kettle reaching the boil is enough by Australian guidance
Sediment filter (5–50 µm)Dirt, rust, particlesMicrobes, dissolved chemicalsProtects later stages; replace when pressure drops
Activated carbonTaste, odour, chlorine, many organic chemicalsMost microbes, nitrates, saltsCertified to NSF/ANSI 42 (taste) or 53 (health effects)
Ultraviolet (UV)Bacteria, viruses, protozoaChemicals; anything shaded by cloudy waterNeeds clear water and power (about 20–50 W). NSF/ANSI 55 Class A for drinking; replace the lamp yearly
Ceramic or hollow-fibre filters (0.1–0.2 µm)Bacteria, protozoaMost viruses, chemicalsGood gravity or portable option; look for NSF/ANSI P231 or similar for purifiers
Reverse osmosisMost chemicals, salts, lead, nitrates, microbes–Wastes water, needs pressure; leaves water very soft (NSF/ANSI 58)
ChlorineBacteria, viruses (some protozoa resist it)Chemicals, CryptosporidiumFor tanks, Australian guidance: about 40 mL of 12.5% sodium hypochlorite per 1,000 L for a remedial dose, aiming for at least 0.5 mg/L free chlorine after 30 minutes

6. Pumps, pressure and power

PumpTypical powerGood for
12/24 V diaphragm pump (van and cabin)50–100 W while running10–20 L/min at 2–3.5 bar; vans, boats, small cabins on solar
Mains pressure pump with pressure switch400–1,000 WHomes on tank water
Submersible bore pump750–2,200 W (often 240 V)Wells and bores; big start-up surge (3–5×)
Solar direct-drive bore pump200–1,000 W of panels, no batteryPumping to a header tank during the day
Hand pumpNoneBackup for shallow wells in an outage

7. Stopping pipes and tanks freezing

8. Greywater and waste

9. Water in vans and boats

10. Emergency water at home

11. Maintenance and testing

WhenTask
Every 3–6 monthsClean gutters, leaf guards and first-flush diverter; check screens
Every 6–12 monthsReplace sediment and carbon filters (or by the pressure gauge); check tank lids and seals
YearlyReplace the UV lamp and clean its quartz sleeve; lab-test drinking water (more often for wells)
Every 2–3 yearsInspect the tank for sediment and desludge if needed
After floods, fires or dead animalsTest, disinfect or drain, and clean before drinking again

12. Rules by country

UKUSAAustralia
Is rainwater collection legal?Yes, freelyYes in all states, but some limit it: Colorado allows up to 110 US gallons (two barrels) per home for outdoor use; Utah requires free registration and caps storage at 2,500 gallons; large cisterns in Oregon and Washington may need a water rightYes, and often required for new homes (for example NSW BASIX and other state building rules)
Standards for rainwater systemsBS 8515 (rainwater harvesting); BS 8525 (greywater)IPC/UPC plumbing codes (non-potable rainwater); ARCSA/ASPE 63AS/NZS 3500 (plumbing); enHealth guidance on rainwater tanks; AS/NZS 4766 and AS 2070 (tanks)
Protecting the mains supplyWater Supply (Water Fittings) Regulations 1999: rainwater is fluid category 5; mains top-up only through an air gap (type AA or AB). Notify the water company before installing; no cross-connectionsPlumbing codes require an air gap or approved backflow preventer, and labelled non-potable pipeworkAS/NZS 3500: backflow prevention device and a licensed plumber; labelled rainwater pipework
Private drinking-water suppliesPrivate Water Supplies Regulations (England 2016; separate rules in Wales, Scotland and NI): councils risk-assess supplies serving more than a single private home, or any commercial or rented usePrivate wells are the owner's responsibility; EPA recommends yearly testing for coliforms and nitrates; state health departments set well-construction rulesOwner's responsibility; state health departments publish guidance (based on the Australian Drinking Water Guidelines)
Well and bore constructionAbstraction over 20 m³/day needs an Environment Agency (or equivalent) licenceState well permits and licensed drillersState bore licences and licensed drillers
Treatment product standardsWRAS-approved fittings; Drinking Water Inspectorate guidanceNSF/ANSI 42, 53, 55, 58, P231WaterMark certification for plumbing products

13. Frequently asked questions

Is rainwater safe to drink?

It can be, from a clean roof and a well-maintained tank, but it can carry bacteria and parasites from bird and animal droppings. Filter it and disinfect it (UV, boiling or chlorine) before drinking, and test it.

How much rainwater can I collect from my roof?

Roughly roof area in square metres × rainfall in millimetres × 0.8 litres. A 50 m² roof with 800 mm of rain a year gives about 32,000 litres a year.

Is it illegal to collect rainwater?

Not in the UK or Australia. In the US it's legal in every state, but a few (notably Colorado and Utah) limit how much you can store.

How long should I boil water to make it safe?

Bring it to a rolling boil. The US CDC advises one minute (three minutes above about 2,000 m altitude). Boiling doesn't remove chemicals or lead.

What size water pump do I need for a cabin?

For a small cabin, a 12 V diaphragm pump giving 10–20 L/min at 2–3 bar with a small pressure tank is usually enough, and uses 50–100 W only while running.

Can I connect my rainwater tank to my mains plumbing?

Only with approved backflow protection, usually an air gap, and in the UK you must notify the water company first. Never connect them directly.

14. Sources

  1. enHealth, guidance on the use of rainwater tanks (Australian Government): cdc.gov.au
  2. WRAS, alternative water systems guidance (2024): wras.co.uk
  3. UK legislation, Water Supply (Water Fittings) Regulations 1999: legislation.gov.uk
  4. Colorado State University Extension, harvesting rainwater under Colorado rules: colostate.edu
  5. MyRainPlan, rainwater harvesting laws by state (2026): myrainplan.com
  6. US CDC, how to create an emergency water supply: cdc.gov
  7. US EPA, private drinking water well programs in your state: epa.gov
  8. NSW Health, rainwater tanks: health.nsw.gov.au
  9. Better Health Channel (Victoria), water quality in tanks, bores and dams: betterhealth.vic.gov.au

General guidance only. Plumbing connected to a public supply must be done by a qualified plumber in line with local rules; get drinking water tested.

New to some of the terms? See the glossary. Not sure where to start? Try start here.