Micro-hydro power calculator

Enter the vertical drop (head), the water flow you can use, and your pipe. The calculator works out the friction loss in the pipe, the net head, and the power and daily energy the turbine can deliver.

Measure in the driest months, and leave the flow your licence requires in the stream.
%
Small Pelton or Turgo systems: 50–70% from water to battery.

Results

Pipe friction loss—
Net head—
Water speed in the pipe—
Power output—
Energy per day—

How it's worked out

Pipe loss (m) = 10.67 × L × Q^1.852 ÷ (C^1.852 × d^4.87) (Hazen-Williams) Net head = gross head − pipe loss Power (W) = 9.81 × flow (L/s) × net head (m) × efficiency

Typical results

FlowNet headPower at 55%Energy per day
1 L/s30 mAbout 160 WAbout 3.9 kWh
2 L/s20 mAbout 215 WAbout 5.2 kWh
5 L/s10 mAbout 270 WAbout 6.5 kWh
10 L/s30 mAbout 1.6 kWAbout 39 kWh

A few hundred watts running all day matches several kilowatts of solar in a northern winter. For measuring head and flow, turbines, dump loads and the licences you need in the UK, US and Australia, see the micro-hydro guide.

Frequently asked questions

How much power can I get from a stream?

Multiply 9.81 × flow in litres per second × net head in metres × efficiency (about 0.5–0.7). A stream giving 2 L/s with 20 m of head produces about 200 W, or 5 kWh a day.

What size pipe do I need for micro-hydro?

One big enough that friction loses no more than 10–15% of the head and the water moves at under about 3 m/s. Longer runs and higher flows need much larger pipe.

Is high head or high flow better?

High head with low flow is usually cheaper: smaller pipe, smaller turbine and less civil work for the same power.