Home › Guides › Testing battery capacity

Testing battery capacity

Why test, equipment, the basic method, lead-acid batteries, lithium batteries, working out state of health, quicker checks, and safety.

By Michael Johnson · Updated 19 November 2026 · How we check our guides

A battery's label tells you what it held when new. After a few years, or if you've bought it second-hand, the only way to know what it really holds is a capacity test: charge it fully, then discharge it at a steady, known rate and measure how many amp-hours come out before it reaches its cut-off voltage. This guide explains when to test, the equipment you need, step-by-step methods for lead-acid and lithium batteries, how to work out state of health, other quicker checks, and safety.

Never discharge below the battery's safe cut-off voltage, and recharge lead-acid batteries straight after a test. Test in a ventilated area away from anything flammable, and watch the battery and cables for heat.

1. Why test capacity

2. Equipment

ItemUse
Battery monitor with shuntCounts amp-hours out accurately. See the battery monitoring guide
DC electronic loadDraws a set, constant current and often logs amp-hours
Known load (lights, heater, inverter and appliance)Works if you measure current and time
MultimeterChecks voltage at the terminals. See the multimeter guide
Suitable chargerFor a full charge before and after

3. The basic method

  1. Charge the battery fully with a proper charger, including the absorption stage; let it rest a few hours.
  2. Note the temperature: capacity is usually quoted at around 20–25 °C, and a cold battery tests low.
  3. Apply a steady load at a set rate (for example the 20-hour rate for lead-acid: capacity ÷ 20 amps).
  4. Record amp-hours (or current × hours) until the voltage under load reaches the cut-off.
  5. Stop, and recharge.

The battery capacity test calculator works out the result from your current, time and rated capacity.

4. Lead-acid batteries

5. Lithium (LiFePO4) batteries

6. Working out state of health

State of health (%) = measured capacity ÷ rated capacity × 100

ResultWhat it usually means
90% or moreHealthy
80–90%Some ageing; still useful
Below about 80%Commonly treated as end of life for demanding uses; fine for lighter duty if it holds voltage under load

Example: a 100 Ah battery that gives 78 Ah at the 20-hour rate is at 78% state of health.

7. Quicker checks

8. Safety

9. Frequently asked questions

How do I test the capacity of a 12 V leisure battery?

Charge it fully, then discharge at the 20-hour rate (capacity ÷ 20 amps) while counting amp-hours until it reaches about 10.5 V under load, then recharge straight away.

Can I tell capacity from voltage?

No. Voltage shows state of charge (and for lithium, only roughly). Capacity needs a measured discharge.

When should I replace a battery?

Commonly when capacity falls below about 80% of its rating for demanding uses, or when it can't hold voltage under load.

10. Sources

  1. PVEducation, special considerations for lead-acid batteries: pveducation.org
  2. Victron Energy, Wiring Unlimited: battery bank wiring: victronenergy.com
  3. Victron Energy, lithium-ion vs AGM: victronenergy.com

New to some of the terms? See the glossary. Not sure where to start? Try start here.