Testing battery capacity
Why test, equipment, the basic method, lead-acid batteries, lithium batteries, working out state of health, quicker checks, and safety.
By Michael Johnson · Updated 19 November 2026 · How we check our guides
A battery's label tells you what it held when new. After a few years, or if you've bought it second-hand, the only way to know what it really holds is a capacity test: charge it fully, then discharge it at a steady, known rate and measure how many amp-hours come out before it reaches its cut-off voltage. This guide explains when to test, the equipment you need, step-by-step methods for lead-acid and lithium batteries, how to work out state of health, other quicker checks, and safety.
1. Why test capacity
- To see how much life is left in an ageing battery bank.
- To check a second-hand battery before you rely on it. See the used batteries guide.
- To find a weak battery in a bank (each battery tested separately).
- To size a replacement correctly.
2. Equipment
| Item | Use |
|---|---|
| Battery monitor with shunt | Counts amp-hours out accurately. See the battery monitoring guide |
| DC electronic load | Draws a set, constant current and often logs amp-hours |
| Known load (lights, heater, inverter and appliance) | Works if you measure current and time |
| Multimeter | Checks voltage at the terminals. See the multimeter guide |
| Suitable charger | For a full charge before and after |
3. The basic method
- Charge the battery fully with a proper charger, including the absorption stage; let it rest a few hours.
- Note the temperature: capacity is usually quoted at around 20–25 °C, and a cold battery tests low.
- Apply a steady load at a set rate (for example the 20-hour rate for lead-acid: capacity ÷ 20 amps).
- Record amp-hours (or current × hours) until the voltage under load reaches the cut-off.
- Stop, and recharge.
The battery capacity test calculator works out the result from your current, time and rated capacity.
4. Lead-acid batteries
- Rated capacity is usually at the 20-hour rate (C20). A 100 Ah battery is tested at about 5 A.
- Common end voltage at the 20-hour rate: about 10.5 V for a 12 V battery (1.75 V per cell). Check the maker's figure.
- At higher currents, lead-acid delivers fewer amp-hours (Peukert's effect), so a fast test reads low. See the Peukert calculator.
- For flooded batteries, check electrolyte levels first and use a hydrometer to spot a weak cell.
- Recharge immediately: leaving lead-acid flat causes sulphation. See the lead-acid care guide.
5. Lithium (LiFePO4) batteries
- Capacity changes little with discharge rate, so a moderate rate (for example 0.2C, which is 20 A for a 100 Ah battery) is fine.
- Stop at the maker's recommended cut-off, or let the BMS end the test; LiFePO4 voltage falls steeply near empty.
- Don't rely on voltage alone: LiFePO4 voltage is very flat over most of its range, so count amp-hours.
- Many batteries with Bluetooth BMS apps show their own capacity estimate, but a measured discharge is more trustworthy.
- A battery monitor needs a full charge to resynchronise after a test. See the lithium BMS guide.
6. Working out state of health
State of health (%) = measured capacity ÷ rated capacity × 100
| Result | What it usually means |
|---|---|
| 90% or more | Healthy |
| 80–90% | Some ageing; still useful |
| Below about 80% | Commonly treated as end of life for demanding uses; fine for lighter duty if it holds voltage under load |
Example: a 100 Ah battery that gives 78 Ah at the 20-hour rate is at 78% state of health.
7. Quicker checks
- Rest voltage after a full charge and several hours' rest shows state of charge for lead-acid, but not capacity.
- Internal resistance testers spot ageing batteries and weak cells quickly; rising resistance is an early warning.
- Load testers for car batteries check cranking ability, not deep-cycle capacity. See the car battery guide.
8. Safety
- Fuse the test load's cable at the battery.
- Resistive loads get very hot; keep them on non-flammable surfaces.
- Lead-acid batteries give off hydrogen on charge; ventilate.
- Stop the test if a battery or connection gets hot, swells or smells. See the lithium safety guide.
9. Frequently asked questions
How do I test the capacity of a 12 V leisure battery?
Charge it fully, then discharge at the 20-hour rate (capacity ÷ 20 amps) while counting amp-hours until it reaches about 10.5 V under load, then recharge straight away.
Can I tell capacity from voltage?
No. Voltage shows state of charge (and for lithium, only roughly). Capacity needs a measured discharge.
When should I replace a battery?
Commonly when capacity falls below about 80% of its rating for demanding uses, or when it can't hold voltage under load.
10. Sources
- PVEducation, special considerations for lead-acid batteries: pveducation.org
- Victron Energy, Wiring Unlimited: battery bank wiring: victronenergy.com
- Victron Energy, lithium-ion vs AGM: victronenergy.com
New to some of the terms? See the glossary. Not sure where to start? Try start here.