Home › Guides › Battery monitoring

Battery monitoring: shunts, BMS apps and voltage

Three ways to measure state of charge, why voltage misleads with lithium, how shunt monitors work and how to set and synchronise one, what lithium BMS apps can tell you, capacity tests and tracking battery health, and monitoring several batteries.

By Michael Johnson · Updated 17 November 2026 · How we check our guides

"How much battery have I got left?" sounds like a simple question, but a voltmeter often gives the wrong answer, especially with lithium. This guide explains how battery state of charge is measured, how shunt-based monitors work and how to set them up, what lithium battery apps can and can't tell you, how to use voltage charts properly, and how to track battery health over time.

Quick tools: the battery voltage chart, the battery run time calculator and the Peukert calculator for lead-acid capacity at high loads.

1. Three ways to measure state of charge

MethodHow it worksAccuracyBest for
VoltageReads the battery voltage and compares it with a chartFair for lead-acid at rest; poor for lithium mid-rangeQuick checks
Shunt monitor (coulomb counting)Measures every amp in and out and counts amp-hoursGood (within a few %) if synchronised regularlyAny system, especially mixed charging sources
Lithium BMSThe battery's own electronics count current and track cellsGood if the BMS is decent and synchronisedLithium batteries with Bluetooth

2. Voltage: useful but limited

Use the battery voltage chart for each chemistry.

3. Shunt-based battery monitors

4. Setting up a shunt monitor

  1. Install the shunt in the main negative, battery side to the battery, and every other negative on the system side.
  2. Connect the monitor's positive sense lead to the battery positive with a small fuse.
  3. Enter the battery capacity (Ah) and chemistry.
  4. Set the charged voltage just below your charger's absorption voltage (for example 13.2–13.3 V for lead-acid floats, 14.0–14.1 V for LiFePO4 charging at 14.2–14.4 V), the tail current (about 2–4% of capacity) and the detection time.
  5. Set the Peukert exponent (about 1.05 for lithium, 1.1–1.3 for lead-acid) and charge efficiency (about 99% for lithium, 85–95% for lead-acid).
  6. Synchronise by charging to 100%: the monitor resets when it sees the charged voltage and tail current.
  7. Recharge fully at least every week or two so small errors don't build up.

5. Lithium BMS apps

6. Tracking battery health

7. Several batteries and banks

8. Frequently asked questions

Why does my lithium battery voltage barely change?

LiFePO4 has a very flat voltage curve: it stays around 13.1–13.3 V between about 20% and 90%. Use a shunt monitor or the battery's app for state of charge.

Do I need a battery monitor?

For anything beyond a simple system, yes. A shunt monitor shows exactly what's going in and out, which makes it easy to size solar, spot drains and avoid flattening the battery.

Why does my battery monitor show the wrong percentage?

Usually it hasn't been synchronised (charge to 100%), the capacity or charged-voltage settings are wrong, or some current bypasses the shunt.

How accurate are battery voltage charts?

For lead-acid at rest, within about 10%. For lithium, only near full or empty. Readings under load or while charging are misleading.

9. Sources

  1. Victron Energy, which solar charge controller: PWM or MPPT (system design notes): victronenergy.com
  2. BoatUS, the latest on lithium batteries: boatus.com

New to some of the terms? See the glossary. Not sure where to start? Try start here.