Home › Guides › 12V wiring basics

12V wiring basics: cable, fuses, crimps and layout

Five rules that prevent most 12 V fires, choosing cable, the types of fuse and where they go, crimping lugs and terminals, bus bars and fuse boxes, colour codes, routing and protection, tools, and testing a system before you switch on.

By Michael Johnson · Updated 17 November 2026 · How we check our guides

Most 12 V fires and failures come down to the same handful of mistakes: undersized cable, missing or wrong fuses, poor crimps and loose connections. This guide is a practical reference for wiring a van, boat, shed or off-grid system safely: choosing cable, the types of fuse and where they go, crimping lugs properly, bus bars and distribution, colours, layout and testing.

Related: step-by-step builds are in the campervan wiring guide and boat wiring guide. Size things with the DC cable size calculator and fuse size calculator.

1. Five rules that prevent most fires

  1. Every positive cable is protected by a fuse or breaker at its source end (as close as practical to the battery or bus bar).
  2. The fuse protects the cable: the fuse rating must not exceed what the cable can carry.
  3. Size cable for voltage drop as well as current: long 12 V runs need much thicker cable than the current alone suggests.
  4. Every connection is crimped properly, tight and protected from movement and moisture.
  5. Cables are supported, protected from chafing, and away from heat and sharp edges.

2. Choosing cable

Voltage drop (V) = 2 × length (m) × current (A) × 0.0172 ÷ area (mm²) Aim for under 3% on most 12 V circuits (0.36 V), and under 2% for chargers, inverters and fridges

Convert sizes with the AWG to mm² converter.

3. Fuses and breakers: types and where they go

TypeTypical rangeUseNotes
Blade (ATO/ATC, mini, maxi)1–40 A (maxi to 120 A)Branch circuits in a fuse boxCheap and easy; low breaking capacity
MIDI / strip fuse30–200 ACharger, DC-DC, small inverter feedsBolt-down; compact
ANL35–750 AInverter and battery main fuse (lead-acid)Limited breaking capacity for lithium
MRBF (terminal fuse)30–300 AFitted directly on the battery terminalHigh breaking capacity (about 10 kA at 14 V); great for lithium
Class T110–800 AMain fuse on large lithium banks20 kA breaking capacity; fast-acting
DC circuit breakers5–300 AResettable protection, also used as an isolatorMust be DC-rated, with enough breaking capacity

4. Crimping lugs and terminals

  1. Use the right lug for the cable size and stud (for example 35 mm² with an M8 hole). Tinned copper tube lugs are best for heavy cable; avoid thin, stamped lugs.
  2. Strip exactly the length of the lug barrel, without nicking strands.
  3. Crimp with the correct tool: a ratchet crimper for small terminals, and a hydraulic or hex crimper for lugs above about 10 mm². Hammer crimpers give inconsistent results.
  4. Pull test every crimp: it shouldn't move.
  5. Seal with adhesive-lined heat shrink, which keeps out moisture and supports the cable.
  6. Don't solder heavy lugs as the only connection: solder wicks up the strands and they break where flexible meets stiff.
  7. Torque terminals to the maker's figure and recheck after a few weeks.

For photos and the full method, see crimping in the campervan wiring guide.

5. Bus bars, fuse boxes and switches

6. Colours and labelling

UseCommon practice (vehicles, off-grid)Boats (ABYC)Mains AC (UK / US / AU)
DC positiveRedRed–
DC negativeBlackYellow (or black)–
AC live / line–Black or brownBrown / black (red) / brown or red
AC neutral–White or blueBlue / white / blue or black
Earth / ground–Green or green/yellowGreen/yellow / green / green/yellow

Label both ends of every cable, and keep a wiring diagram with the system.

7. Layout, routing and protection

8. Tools worth having

9. Testing before you switch on

  1. With the battery disconnected, check each circuit for continuity and that positive isn't shorted to negative or chassis.
  2. Connect the battery with the main fuse removed, check voltages, then fit the fuse.
  3. Turn on circuits one at a time and check for heat, smell and correct operation.
  4. Run big loads (inverter, charger) at full power for 10–15 minutes and feel cables and lugs: anything more than warm needs attention.
  5. Measure voltage at the load under full current to confirm voltage drop.

10. Frequently asked questions

What size fuse should I use?

About 1.25 times the circuit's normal current, rounded up to the next standard size, and never larger than the cable's current rating. The fuse protects the cable.

Where should the fuse go?

At the battery or bus bar end of the positive cable, as close as practical (within about 300 mm). Fuse both ends if both ends can supply current.

Can I use solid-core cable in a van?

No. Vibration breaks solid cores. Use fine-stranded flexible cable, ideally tinned and rated for 105 °C.

Should I solder or crimp?

Crimp with the correct tool and seal with adhesive heat shrink. Solder alone creates a stiff point where strands break under vibration.

11. Sources

  1. Panbo, ABYC updated battery and electrical standards (2025): panbo.com
  2. Victron Energy, careful – alternator charging lithium: victronenergy.com

New to some of the terms? See the glossary. Not sure where to start? Try start here.