How to wire a campervan: split charging, solar and hook-up
A complete reference design for a van conversion: a 12 V lithium leisure battery charged by a DC-DC charger from the alternator, by 400 W of roof solar and by campsite hook-up. Every battery positive is fused at the terminal and every cable has its own protection. Checked against BS 7671:2018+A4:2026 Section 721 and BS EN 1648-2, with a US section covering NEC Article 551, NFPA 1192 and the RVIA DC standard.
By Michael Johnson · Updated 12 November 2026 · How we check our guides · Open the wiring diagram full size
1. Which rules apply
| Standard | What it covers in a van | Key points used in this design |
|---|---|---|
| BS 7671:2018+A4:2026, Section 721 (caravans and motor caravans) | The 230 V installation: inlet, consumer unit, circuits, earthing and bonding, notices, the hook-up lead | Inlet to BS EN 60309-2, IP44 or better, no higher than 1.8 m above the ground. Main isolator breaking all live conductors. 30 mA RCD breaking all live conductors. Overcurrent devices on every final circuit breaking line and neutral. Flexible or stranded cable, minimum 1.5 mm². Protective bonding of accessible structural metalwork, minimum 4 mm² (Reg 721.411.3.1.2). Instruction notice near the inlet (Figure 721). |
| BS 7671 Amendment 4 (published 15 April 2026, in force since 15 October 2026), new Chapter 57 | Stationary secondary batteries and battery power conversion equipment, such as inverters, inverter/chargers and mains chargers | DC isolators rated for DC (an AC switch doing a DC job is not acceptable). A battery is treated as a source, not a load, and protective devices must suit current flowing both ways where it can (Regs 551.7.1, 530.3.201). The right RCD type upstream of conversion equipment (see RCD type). Battery-presence notices (570.6.8.201) and "WARNING – Isolate both AC and DC sides before servicing" on conversion equipment (570.6.8.203). The article we relied on notes that whether Chapter 57 strictly covers a van leisure battery is open to interpretation, so this design uses it as the benchmark. |
| BS 7671 Section 712 (solar PV), as amended | PV arrays | DC isolation between array and controller. Any DC fuses or breakers rated for at least the array's maximum open-circuit voltage, UOC MAX (Reg 712.533.101(b)). PV conductors not earthed unless the maker says so. Frames bonded. |
| BS EN 1648-2 (12 V ELV installations in motor caravans) | The 12 V habitation system | Overcurrent protection in positive conductors. Battery secured in a protected compartment with terminals marked + and −. Ventilation for vented batteries (minimum 80 mm² low-level vent). Voltage-drop limits; this design aims for 3% or less from battery to appliance. |
| Equipment manuals (Victron and similar) | Fuse sizes, cable sizes, terminal torques, remote-on wiring | Where a manual is stricter than the general rule, follow the manual. |
DVLA reclassification as a motor caravan and the MOT don't inspect the habitation electrics. Insurers and buyers do increasingly ask for an EIC for the 230 V side, so keep it with the van's paperwork.
2. The reference system
This is a typical medium/long-wheelbase panel van build. The numbers carry through every table below. If your parts or cable lengths differ, re-run the checks with the calculators in section 14.
| Part | Example used | Notes |
|---|---|---|
| Leisure battery | 12.8 V 200 Ah LiFePO4 with internal BMS (one battery, or two 100 Ah in parallel) | Combined BMS continuous rating of 200 A or more, so it can supply the optional inverter. Check the BMS surge rating too. |
| Split charge | Victron Orion-Tr Smart 12/12-30 non-isolated DC-DC charger (30 A) | Works with smart (Euro 6) alternators when switched by an ignition or D+ signal. Limits alternator load. |
| Solar | 2 × 200 W panels in series (about 48 V open-circuit) into a Victron SmartSolar MPPT 100/30 | Cold-weather open-circuit voltage stays well below the controller's 100 V limit. |
| Hook-up | 16 A blue inlet → consumer unit → 30 A mains charger + 230 V sockets | A charger on the mains keeps things simple. An inverter/charger is covered in section 9. |
| Distribution | Main fuse → DC isolator → positive busbar with a fuse for each circuit. Negative busbar after a battery-monitor shunt. | Every source and every load has a fuse on its positive cable. |
| Optional inverter | 1200 W pure sine wave inverter feeding its own socket | Not connected to the hook-up circuits. |
3. Wiring diagram
4. Fusing every battery positive
A fuse protects the cable, so it has to sit where the fault current comes from: the battery end. Any battery in the van can feed a short circuit, and that includes the vehicle's starter battery. So:
- Every battery positive gets its own fuse, mounted as close to the terminal as practical. This design aims for 150 mm or less. BS 7671 and EN 1648-2 don't give a UK distance. The US marine standard ABYC E-11 is a sensible guide: within 7 inches (178 mm) of the battery, up to 40 inches if the cable is sheathed, and up to 72 inches (1.8 m) only if it connects directly to the battery terminal and is sheathed along its whole length. The cable between battery and fuse is unprotected, so keep it short, sheathed and well secured.
- The starter battery is fused too. F1 (60 A) sits at the starter battery positive on the DC-DC feed cable. Without it, a chafed 25 mm² cable running the length of the van would be connected straight to a battery that can deliver well over 1,000 A.
- Batteries in parallel each get their own fuse (F8 and F9) before they join. A shorted cell in one battery then can't dump the other battery's energy into it. Use equal cable lengths so the batteries share current evenly. Two fuses in parallel add up: two 200 A fuses can let up to 400 A into the main cable C6 without either blowing. So with two batteries, fit a further main fuse F10 (Class T 200 A) after the junction, ahead of the isolator S1 and C6. The alternative is smaller battery fuses (for example 2 × 125 A, 250 A total, within the rating of C6).
- Charging sources are fused at the busbar end as well. The DC-DC charger, MPPT and mains charger outputs (F3–F5) are fused where they meet the battery-side busbar, because the battery is the source of fault current in those cables.
- The fuse must be able to break the fault current. A LiFePO4 bank can push several thousand amps into a dead short. A fuse with too low an interrupt rating (AIC) can arc across instead of clearing.
"Maxi fuse or similar": which fuse where
| Fuse type | Interrupt rating (AIC) | Range | Use it for |
|---|---|---|---|
| Class T | 20,000 A (at up to 125–160 V DC) | Up to 400 A+ | Main lithium battery fuse (F8, F9). This is the safest choice for large LiFePO4 banks. |
| MRBF terminal fuse (Blue Sea or similar) | 10,000 A at 14 V DC | 30–300 A | Battery-terminal fusing at 12 V, including F1 on the starter battery. It mounts in a terminal fuse block, not loose on the post. It's also acceptable as a 12 V lithium main fuse. |
| MEGA / ANL in a holder | Lower (around 2,000 A for MEGA; check the maker's data) | 40–500 A | Circuit fuses on the busbar (F3–F7), once their interrupt rating has been checked against the battery's fault current (see below). |
| MIDI | Lower; check the maker's data | 30–200 A | Branch circuits on the busbar. |
| Maxi blade | 1,000 A at 32 V DC (Littelfuse data) | 20–80 A | Small 20–80 A branch circuits, only where its interrupt rating is at least the fault current available at that point. Not recommended directly on a lithium battery terminal, because 1,000 A interrupt is too low for its possible fault current. |
So yes: there's a fuse on the positive side of every battery. On the battery terminals, use Class T or MRBF rather than Maxi, because their interrupt rating matches what a lithium or starter battery can deliver.
5. Protection and cable schedule
Rule for every line: load current × 1.25 ≤ fuse rating ≤ cable current rating. The largest cables (C6, C7) need 105 °C-rated cable (tri-rated or welding flex), run singly rather than bundled, to carry their fuse rating. Voltage drops are at copper resistance at 20 °C for the stated one-way lengths. Measure your own runs.
| Ref | Location | Protects | Device | Rating | Cable | Length / current | Volt drop |
|---|---|---|---|---|---|---|---|
| F1 | Starter battery +, ≤150 mm (the positive post; fit nothing to the negative post if it carries an IBS sensor) | C1 DC-DC feed | MRBF in terminal block | 60 A | C1 25 mm² | 5 m / 38 A input | 0.26 V (2.0%) |
| F2 | Ignition / D+ source | Remote signal wire | Blade fuse (in-line) | 2 A | 0.75–1 mm² | signal only | – |
| F3 | Busbar | C2 DC-DC output | MEGA / MIDI | 60 A | C2 16 mm² | 1 m / 30 A | 0.06 V (0.5%) |
| – | PV DC isolator | Isolation of array | 2-pole DC-PV switch | Current ≥ 1.25 × Isc (≈15 A; a 32 A part is fine). Voltage ≥ cold Voc (use ≥ 100 V DC) | C3 6 mm² PV (H1Z2Z2-K) | 6 m / 11.5 A | 0.40 V (1.1% of 37 V) |
| F4 | Busbar | C4 MPPT output | MEGA / MIDI | 40 A | C4 10 mm² | 1 m / 30 A | 0.10 V (0.8%) |
| F5 | Busbar | C5 mains charger output | MEGA / MIDI | 40 A | C5 10 mm² | 1.5 m / 30 A | 0.16 V (1.2%) |
| F6 | Busbar | C8 feed to 12 V fuse box | MEGA / MIDI | 50 A | C8 16 mm² | 2 m / 40 A max | 0.17 V (1.3%) |
| F7 | Busbar | C7 inverter (optional) | MEGA | 150 A | C7 35 mm², 105 °C | 1.5 m / 115 A | 0.17 V (1.3%) |
| F8 | Leisure battery 1 +, ≤150 mm | C6 main cable (one battery); battery 1 lead (two batteries) | Class T (or MRBF) | 200 A | C6 50 mm², 105 °C | 1 m / 150 A peak | 0.10 V (0.8%) |
| F9 | Leisure battery 2 +, ≤150 mm (if fitted) | Its own cable to the junction | Class T (or MRBF) | 200 A | 50 mm², equal length to battery 1 | – | – |
| F10 | After the battery junction (only with two batteries) | C6 and S1 | Class T | 200 A | C6 50 mm², 105 °C | – | – |
| S1 | After F8/F9 | Main isolation | DC battery isolator switch | ≥ 250 A continuous, DC rated | 50 mm² | – | – |
| C9 | Negative busbar → body earth point | Common negative return for the DC-DC charger | No fuse (negative) | – | 25 mm² (same as C1) | < 1 m | – |
12 V final circuits (from the fuse box)
| Circuit | Typical current | Fuse | Cable | One-way length | Drop incl. feed |
|---|---|---|---|---|---|
| Compressor fridge | 6 A | 15 A (or as the fridge manual says) | 4 mm² | 4 m | 2.5% |
| Diesel heater | 10 A at start-up | 20 A (or as the manual says) | 4 mm² | 3 m | 2.9% |
| Water pump | 7 A | 10 A | 4 mm² | 4 m | 2.7% |
| LED lighting | 4 A | 7.5 A | 2.5 mm² | 4 m | 2.5% |
| USB / 12 V sockets | 10 A | 15 A | 6 mm² | 4 m | 2.6% |
| Roof fan | 4 A | 7.5 A | 2.5 mm² | 3 m | 2.1% |
Total drop = fuse-box feed (0.11 V at a typical 25 A) + the branch run, as a percentage of 12.8 V. At the full 40 A feed current the worst circuit (the heater) reaches about 3.4%, so use larger cable if you often run everything at once. Every final circuit's fuse is at or below the conservative bundled current rating of its cable, so bundling these runs in a loom is fine.
6. Split charging with a DC-DC charger
- Why DC-DC and not a relay (VSR): Euro 5/6 smart alternators drop their output voltage once the starter battery is full, and lithium needs a proper charge profile. A DC-DC charger fixes both, and caps the alternator load at about 30 A output (about 38 A input).
- Switching it on: remove the factory wire loop between the L and H pins. Feed the H pin from an ignition-switched live or the alternator D+ through F2 (2 A). The charger then only runs with the engine on. Victron's engine-shutdown detection can also use an external engine-running signal on the L pin (over 7 V). That signal works alongside remote on/off and doesn't replace it.
- Fuse both ends: F1 at the starter battery (its cable C1 runs the length of the van) and F3 at the leisure busbar. Victron specifies a 60 A fuse for the 12 V model.
- Cable: Victron's minimum for 5–10 m is 16 mm². This design uses 25 mm² for a 5 m run, which keeps the input drop near 2% so the charger doesn't throttle on a hot cable.
- Negative: the non-isolated Orion shares one negative between input and output. Its input negative must reach the vehicle negative. This design uses the leisure negative busbar plus C9, a 25 mm² link to a manufacturer's body earth point. Land C9 on the load side of the shunt so the battery monitor still sees all charge and discharge current. Many Euro 6 vans have an intelligent battery sensor (IBS) on the starter battery negative. Never connect to that negative post: use a body earth point so the vehicle's charging system still measures every amp.
- Run C1 in convoluted conduit, away from the exhaust and moving parts. Use rubber grommets wherever it passes through metal, and fix it at least every 300 mm.
7. Solar
- Series wiring: two 200 W panels in series give about 48 V Voc. In a −10 °C morning that rises roughly 10%, to about 53 V, well inside the MPPT 100/30's 100 V limit. With only one string there's nothing that can back-feed a fault, so no string fuses are needed. Three or more parallel strings would need string fuses rated for the array voltage.
- PV DC isolator between the roof gland and the controller. It must be a 2-pole switch rated for DC PV at or above the cold Voc. An AC switch is not acceptable, and Amendment 4 is explicit that DC isolators must be DC rated.
- Cable: 6 mm² solar cable (H1Z2Z2-K, UV-resistant, double insulated), with MC4 connectors crimped using the proper tool. Use a sealed roof gland.
- Order: connect the battery to the MPPT first, then the PV. Disconnect in reverse. Never earth PV+ or PV−. Bond the panel frames and mounting rails to the van body.
- Output: F4 40 A on 10 mm² (Victron's recommendation for the 100/30 is a 35–40 A battery fuse).
8. 230 V hook-up (shoreline)
Inlet and incoming cable
- Blue 16 A 2P+E inlet to BS EN 60309-2, IP44 minimum. Mount it in a recessed housing with a cover, no more than 1.8 m above the ground.
- Run 2.5 mm² 3-core flexible cable from the inlet to the consumer unit by the shortest practical route. Fix it, protect it where it passes through metal, and keep it out of the gas locker.
Consumer unit
- Main isolator breaking line and neutral (both poles), because campsite polarity can be reversed.
- 30 mA RCD (BS EN 61008 or RCBO to BS EN 61009) breaking all live conductors and covering every circuit.
- Double-pole MCBs (or double-pole RCBOs) on each final circuit. In this design: MCB1 B10 for the sockets on 2.5 mm² flex, and MCB2 B6 for the mains charger on 1.5 mm² flex.
- Purpose-made caravan/motorhome consumer units (for example 2-way RCD and MCB units) meet these points out of the box.
RCD type
- Type AC is not suitable. Chargers, inverters and LED drivers can produce DC components that blind a Type AC RCD.
- Type A is the normal minimum for a van with a mains battery charger.
- Battery power conversion equipment (inverter/chargers) under Amendment 4 (Chapter 57): the RCD on its AC supply should be Type B. The exceptions are where the equipment provides separation, a separate transformer does, or the maker says Type B isn't needed. Victron's manuals for the MultiPlus-II and Quattro-II say their internal mains-frequency transformer means Type A RCDs can be used. High-frequency or transformerless units may need Type B. Check the manual of whatever unit you fit and record the decision on the EIC.
- RCDs in series must be compatible (Reg 531.3.3 note). For example, a Type AC upstream of a Type A can be impaired. That matters if you add a second RCD after an inverter/charger.
Earthing, bonding and wiring
- Bond accessible structural metalwork (the van body or chassis) to the consumer unit earth bar with a 4 mm² green/yellow conductor, using a crimped ring terminal on a cleaned, protected earth point (Reg 721.411.3.1.2).
- Use flexible or stranded cable throughout, minimum 1.5 mm². Support cables not in conduit at no more than 0.25 m on horizontal runs and 0.4 m on vertical runs, and protect them where they pass through metal or near sharp edges.
- Terminate fine-strand flex in the consumer unit with bootlace ferrules or terminals suitable for fine strands, so strands can't splay (Reg 526.9.1).
- Keep 230 V and 12 V cables apart, or separate them with a barrier or a separate conduit. Never put electrics in the gas locker.
- Use 230 V sockets to BS 1363 (or BS EN 60309-2 types), sited away from water and the hob.
Hook-up lead
- 25 m (±2 m) flexible cable, 2.5 mm² for 16 A, with a BS EN 60309-2 plug and connector. Before Amendment 4 the lead was H05RN-F (rubber) or equivalent. One A4 summary reports that Reg 721.55.2.6(b) now names H05VV-F, with an orange sheath recommended; we couldn't confirm this against the printed text, so check your copy. Rubber H05RN-F or H07RN-F remains the tougher choice for a lead that lies outdoors and gets walked on.
- Always uncoil the lead completely before use. A coiled lead can overheat at 16 A.
Notices and labels
- The Figure 721 instruction notice next to the inlet. It explains how to connect and disconnect, and says to check the supply and have the installation inspected.
- Periodic inspection label: recommended every 3 years, or every year for frequently used or high-mileage vans.
- Amendment 4 notices, used here as good practice: a battery-presence notice at the consumer unit (570.6.8.201), and "WARNING – Isolate both AC and DC sides before servicing" on the mains charger and any inverter (570.6.8.203).
- Label the DC isolator, the PV isolator and every fuse (F1–F9) to match the schedule.
9. Adding an inverter
- Simplest and safest: a standalone inverter feeding its own labelled socket (as in the diagram). It is never connected to the hook-up wiring, so there's no back-feed or changeover question. Earthing and RCD protection of that socket still depend on the inverter: many small inverters have a floating output. Follow its manual, or choose a unit with a built-in RCD and neutral-earth bond. Fuse it at the busbar (F7) and size the cable for the full DC current. For 1200 W that's about 115 A, on 35 mm² 105 °C cable.
- Running the van's 230 V sockets from the inverter needs a 2-pole changeover switch or automatic transfer relay, so the inverter can never feed the hook-up inlet. It also needs a correct neutral-earth bond in inverter mode (per the inverter's manual) and RCD protection on the inverter output. An inverter/charger (such as a Victron MultiPlus) does this internally with a transfer switch and earth relay. This route should be designed with your electrician, because it changes the RCD-type and earthing decisions above.
- Battery BMS, main fuse F8 and cable C6 must all be rated for the inverter's continuous and surge current. A 1200 W inverter can surge to around 230 A for a moment, which can trip a 200 A BMS. Check the BMS surge rating.
10. Installation practice
- Battery mounting: secure it with a clamp or bracket bolted to the structure, strong enough to hold it in a collision (not just ratchet straps or Velcro). It should sit in a protected compartment with terminals covered and marked + and −. Sealed LiFePO4 doesn't gas. Vented lead-acid needs a vent to outside of at least 80 mm² at low level.
- Temperature: most LiFePO4 must not be charged below 0 °C. Fit batteries inside the heated living space or choose a self-heating battery.
- Cable: fine-stranded tinned copper (tri-rated or automotive thin-wall to ISO 6722 / ISO 19642 for 12 V). Use red for positive and black for negative throughout.
- Terminations: every crimp must be made with the correct tool and die for that cable and lug. This is critical on the high-current cables, so it has its own section: see section 11.
- Routing: use grommets or glands through all metal, and convoluted conduit in the engine bay and under the floor. Keep cables clear of exhaust, fuel lines and sharp edges, and away from the gas locker.
- Isolation: the DC isolator (S1) must be within reach. Switch off the PV isolator and chargers before opening S1, so the solar and DC-DC chargers are never left running with no battery connected. The battery monitor shunt goes on the battery negative, and nothing else connects directly to the battery negative post.
11. Crimping: the joint is part of the protection
Why it matters: the numbers
Heat in a joint = current² × resistance. A poor crimp with just 1 milliohm of extra resistance gives off:
| Cable | Current | Heat in a 1 mΩ bad joint |
|---|---|---|
| Fridge circuit, 4 mm² | 6 A | 0.04 W (harmless) |
| DC-DC feed C1, 25 mm² | 38 A | 1.4 W |
| Inverter cable C7, 35 mm² | 115 A | 13 W |
| Main battery cable C6, 50 mm² | 150 A | 22.5 W, as much as a soldering iron, inside a lug |
The heat oxidises the copper, the resistance rises, so it runs hotter still. On high-current cables a bad crimp gets worse over time, and the vibration of a moving van speeds that up. That's why the large cables need the most care.
Use the correct tool for the job
| Cable size | Terminal | Correct tool | Don't use |
|---|---|---|---|
| 0.5–6 mm² (final circuits) | Pre-insulated crimps (red 0.5–1.5, blue 1.5–2.5, yellow 4–6 mm²) or uninsulated terminals sized for the cable | Ratchet crimper with dies matched to the terminal colour or type. It won't release until the crimp is complete. | Cheap "plier" crimpers with a stamped jaw. Pliers. Squashing it with a vice. |
| Fine-strand flex in screw terminals (fuse box, consumer unit, chargers) | Bootlace ferrules sized to the cable | Ferrule ratchet crimper (square or trapezoidal profile) | Tinning the end with solder. It creeps under the screw and works loose. |
| 10–120 mm² (battery, busbar, charger and inverter cables) | Tinned copper tube lugs matched to both the cable size and the stud size (for example 50 mm² × M8) | Hydraulic crimper with a hexagonal die marked for that cable size, or a long-handled mechanical lug crimper made for that size range | Hammer/anvil crimpers. Mismatched dies ("close enough"). Lugs for a bigger cable with the gap packed out. Copper pipe cut and squashed. |
Making a good high-current crimp, step by step
- Match everything: cable cross-section = lug barrel size = die size. Choose lugs made for fine-strand (flexible) cable. They have a larger barrel than lugs for solid-core building wire.
- Cut square with proper cable cutters, not a hacksaw that frays strands.
- Strip to the barrel depth. All strands must go into the barrel, with none bent back or cut off to make it fit. The copper should just show in the inspection hole and the insulation should butt up to the barrel.
- Crimp with the die marked for that size. On long barrels, do two crimps working from the palm end towards the cable. Never crimp over the inspection hole area of a lug designed with one.
- Inspect: an even, symmetrical hex shape with no cracks in the barrel, no flash squeezed out of the die and no loose strands.
- Pull test: a firm hand pull must not move the lug at all. If it moves, cut it off and start again. Never re-crimp a bad one.
- Seal: adhesive-lined (dual-wall) heat-shrink over the barrel and onto the insulation, red for positive and black for negative. It keeps moisture out and supports the cable.
- Bolt up correctly: lug flat against the busbar or terminal, with nothing (no washers) between the lug and the contact face. Put the washer and spring washer or nyloc nut on top. Torque to the device maker's figure and mark with torque paint so you can see later if it has moved.
Solder and other shortcuts
- Don't rely on solder alone on any battery or high-current cable. Solder softens if the joint overheats, and that's exactly when you need it to hold.
- Don't flood a good crimp with solder. It wicks up the strands and makes a stiff point where the cable then cracks from vibration.
- Don't use pre-made "universal" cables of unknown quality for main battery or inverter runs unless the crimp quality is visibly good and the lugs are the right size.
- If you only need a few large lugs, many marine and auto-electrical suppliers will make up cables to length on a calibrated hydraulic press. That's a good option if you don't want to buy the tool.
Check every joint once the system is running
- Voltage-drop test: with a heavy load running (inverter, or the DC-DC charger with the engine on), measure millivolts across each joint, from the cable to the lug palm. A good crimp shows only a few mV. A joint reading noticeably more than identical joints elsewhere should be remade.
- Heat check: after 30–60 minutes at high load, feel each lug carefully or use a thermal camera. A lug that is warmer than the cable either side is a bad joint.
- Re-check torque after the first few hundred miles, then at every annual service. Vibration and the copper settling under load can loosen bolted joints.
12. Testing and commissioning checklist
12 V side (before connecting the battery)
- Every fuse is fitted at the rating in the schedule, with labels matching.
- Continuity of every positive and negative run. No short between busbars (measure resistance with the battery disconnected).
- Every crimp inspected and pull-tested, and every lug and busbar stud torqued and marked (see section 11).
- Connect the battery with the isolator OFF. Check voltage at the busbar side. Switch on one circuit at a time.
- Program chargers for LiFePO4 (absorption and float voltages from the battery maker), and set the DC-DC charger's engine detection.
- Run the engine and confirm the DC-DC charger starts, delivers its current and stops with the ignition off. Check the voltage drop on C1 under load.
- Check solar charging. Use a clamp meter to confirm each load's current is under its fuse rating.
- Under heavy load, measure the millivolt drop across each high-current joint, and check for warm lugs with a thermal camera or by touch after 30–60 minutes at full load. Remake any joint that stands out.
230 V side (competent person, BS 7671 Part 6)
- Visual inspection: inlet height and IP rating, notices, segregation, cable support.
- Continuity of protective conductors and the bonding conductor to the chassis.
- Insulation resistance (≥ 1 MΩ at 500 V DC). Disconnect sensitive electronics first.
- Polarity at every socket and device.
- RCD operation test at its rated residual current IΔn (30 mA, must trip within 300 ms) and the test button.
- Earth fault loop impedance on a known supply.
- Issue an Electrical Installation Certificate. Fit the next-inspection label.
13. Parts list (example)
| Item | Qty | Specification |
|---|---|---|
| LiFePO4 battery | 1 (or 2) | 12.8 V 200 Ah (or 2 × 100 Ah), BMS ≥ 200 A continuous, low-temperature charge protection |
| DC-DC charger | 1 | Victron Orion-Tr Smart 12/12-30 non-isolated (or equivalent 30 A unit) |
| Solar charge controller | 1 | Victron SmartSolar MPPT 100/30 |
| Solar panels | 2 | 200 W, Voc ≈ 24 V each, with roof brackets and gland |
| PV isolator | 1 | 2-pole DC PV isolator, ≥ 32 A, ≥ 100 V DC |
| Mains charger | 1 | 12 V 30 A LiFePO4-capable (e.g. Victron Blue Smart IP22 12/30) |
| Main fuse(s) | 1 (or 3) | Class T 200 A with holder (or MRBF 200 A with terminal block). With two batteries: one per battery plus F10 after the junction. |
| Starter battery fuse | 1 | MRBF 60 A with terminal fuse block |
| Battery isolator | 1 | DC rated, ≥ 250 A continuous |
| Busbars | 1 set | Positive fused busbar (e.g. Lynx Distributor or MEGA busbar, 4–6 ways) and negative busbar |
| Circuit fuses | – | 60 A, 40 A, 40 A, 50 A (MEGA or MIDI); 150 A MEGA if the inverter is fitted |
| Battery monitor | 1 | Shunt-based (e.g. Victron SmartShunt 500 A) |
| 12 V fuse box | 1 | 6–12 way blade fuse box with negative bus |
| Hook-up inlet | 1 | 16 A 2P+E BS EN 60309-2, IP44, recessed with flap |
| Consumer unit | 1 | Caravan type: DP isolator, 30 mA Type A RCD, DP MCBs B10 + B6 (or DP RCBOs) |
| Cable | – | 50, 35, 25, 16, 10, 6, 4, 2.5 mm² tri-rated red/black. 6 mm² H1Z2Z2-K solar. 2.5 and 1.5 mm² 3-core flex. 4 mm² green/yellow bonding. |
| Crimping tools | – | Hydraulic lug crimper with hex dies for 10–70 mm² (or have the large cables made up by a supplier). Ratchet crimper for insulated terminals. Ratchet ferrule crimper. Proper cable cutters. Torque wrench. |
| Sundries | – | Tinned lugs, heat-shrink, grommets, conduit, P-clips, labels, the Figure 721 notice, the Amendment 4 battery notice |
14. Check your own numbers
Use these OffGridVolts calculators to adapt the design to your van:
- DC cable size calculator and DC voltage drop calculator: for every cable run
- Fuse size calculator: load × 1.25 ≤ fuse ≤ cable rating
- DC-DC charger size calculator
- MPPT string voltage calculator and solar charge controller calculator
- Battery bank size calculator and 12 V power consumption calculator
- Inverter battery current calculator
- Hook-up (shore power) calculator and AC voltage drop calculator
15. Building the same van in the USA
The 12 V design (batteries, DC-DC charger, solar, busbar and fuse layout) carries over almost unchanged to a US build. The shore power side is completely different: 120 V 60 Hz, NEMA connectors, and a different approach to earthing ("grounding"). This section lists what changes and which rules apply.
Which US rules apply
| Standard | Covers | Notes |
|---|---|---|
| NFPA 70 (NEC), Article 551: recreational vehicles. The current edition is 2026; 2023 is still widely adopted. | 120 V / 240 V AC wiring in the RV: inlet and power cord, panelboard, branch circuits, GFCI, grounding and bonding, generators and inverters, factory tests | The AC rules in this section come from Article 551. |
| NFPA 1192: Standard on Recreational Vehicles (2026 edition) | Whole-vehicle standard: fire and life safety, LP gas, plumbing. It points to the NEC for AC and the RVIA standard for DC. | Used by RVIA for certified manufacturers. Mandatory enforcement of the 2026 RVIA standards set began 1 September 2026. |
| ANSI/RVIA DC Voltage Standard (2025 edition; replaced the ANSI/RVIA LV "Low Voltage" standard) | DC systems up to 60 V nominal: batteries, fuses, conductors, routing, splices | The DC figures quoted below are from LV-2020, the edition we could read. Check the 2025 edition if you need certified compliance. The 2025 edition requires lithium batteries to be listed to UL 1973 or UL 2054. |
| ABYC E-11 (boats) | AC and DC on boats | Not an RV standard, but its fuse-placement rules and ampacity tables for large 105 °C cables are widely used in US van builds. We use them below for cables bigger than the RVIA table covers. |
| UL 458 | Inverters, converters and chargers for RVs and boats | Article 551 requires inverters, converters and transfer switches to be listed for RV use. In practice that means UL 458. |
12 V side: what's different
| Topic | US rule (ANSI/RVIA LV-2020 unless stated) | This design |
|---|---|---|
| Fuse location | Overcurrent device within 18 in (457 mm) of where the power source connects to the vehicle circuits, and accessible. ABYC E-11 is stricter: 7 in at the battery. | ≤150 mm (6 in) at every battery positive. This meets both. |
| Fuse vs cable | The fuse must not exceed the conductor ampacity in the standard's tables. Fuses and breakers must be DC rated at or above the system voltage, and breakers must be trip-free. | Same principle. US sizes are in the table below. |
| Cable type | Stranded copper only, to SAE J1127 (battery cable) or J1128 (primary wire), insulation rated at least 90 °C. Use 125 °C in the engine bay and within 10 in of the exhaust. | Use SAE J1127/J1128 cable (SGX/TXL/GXL or marine tinned cable). |
| Battery chassis ground | Battery ground to chassis at least 8 AWG copper, and the same size as the power lead if that is bigger. Converter enclosures are bonded to the frame with 8 AWG. | C9 becomes 2 AWG, to match C1. |
| Separation from 120 V | At least a ½ in (12.7 mm) gap between DC and 120/240 V wiring, or a barrier. | Keep the two systems in separate looms and conduit. |
| Support | Secure conductors at least every 4½ ft (1.4 m). Leave strain relief where parts move, and at least 4 in of free conductor after the last support. | Our 300 mm spacing for heavy cables is well inside this. Keep it: big cables in a moving van need it. |
| Ground returns and hardware | Negative returns must be identifiable (colour or marking). Ground hardware must be plated, on clean metal or with serrated washers. | Black negatives. Use the body earth point as in the main design. |
| Joints and crimps | Connectors must match the conductor size and type. Each splice must pass a 1-minute pull test (e.g. 30 lb for 14 AWG, 40 lb for 10 AWG, 50 lb for 6 AWG). Solder splices must be mechanically secured first. No more than 4 terminals on one stud. | Matches the crimping section. Pull-test every joint, and keep stacks to 4 lugs or fewer per stud. |
| Batteries | Secured and protected. Vented (flooded) batteries need a vapour-resistant box vented to outside, with openings of at least 1.7 in² within 2 in of the top and bottom. Lithium must be listed and installed per its listing. | LiFePO4 inside, clamped. Choose one listed to UL 1973 or UL 2054. |
| Solar | Solar is a recognised DC source. Its circuits need no fuse if the cable can carry the largest current available. The RVIA DC standard covers systems up to 60 V nominal. | Two panels in series ≈ 48 V Voc (≈53 V cold). Keep the array below 60 V, or larger arrays move into NEC Article 690 PV territory. |
US cable and fuse schedule
Each metric cable was replaced by the nearest AWG size that is at least as large, so voltage drops are the same or better than in section 5. Small cables are checked against the RVIA Table 1 ampacities. Battery cables above 2 AWG are checked against ABYC E-11's 105 °C single-conductor ratings outside an engine space (2 AWG 210 A, 1/0 285 A).
| Ref | Circuit | Fuse | UK cable | US cable | US cable rating |
|---|---|---|---|---|---|
| F1 / C1 | Starter battery → DC-DC | 60 A MRBF | 25 mm² | 2 AWG (33.6 mm²) | 100 A (RVIA) |
| F3 / C2 | DC-DC → busbar | 60 A | 16 mm² | 4 AWG (21.2 mm²) | 75 A (RVIA) |
| C3 | PV array → MPPT | none (one string) | 6 mm² PV | 10 AWG PV wire (UL 4703) | > Isc ≈ 11.5 A |
| F4 / C4 | MPPT → busbar | 40 A | 10 mm² | 6 AWG (13.3 mm²) | 55 A (RVIA) |
| F5 / C5 | Converter/charger → busbar | 40 A | 10 mm² | 6 AWG | 55 A (RVIA) |
| F6 / C8 | Busbar → 12 V fuse panel | 50 A | 16 mm² | 4 AWG | 75 A (RVIA) |
| F7 / C7 | Busbar → inverter | 150 A | 35 mm² | 1/0 AWG (53.5 mm²), 105 °C | 285 A (ABYC) |
| F8–F10 / C6 | Battery → isolator → busbar | 200 A Class T | 50 mm² | 1/0 AWG, 105 °C | 285 A (ABYC) |
| C9 | Negative busbar → chassis | – | 25 mm² | 2 AWG (≥ 8 AWG and ≥ C1) | – |
| – | Fridge / heater / pump | 15 / 20 / 10 A | 4 mm² | 10 AWG | 30 A (RVIA) |
| – | Lights / roof fan | 7.5 A | 2.5 mm² | 12 AWG | 20 A (RVIA) |
| – | USB / 12 V sockets | 15 A | 6 mm² | 8 AWG | 40 A (RVIA) |
120 V shore power: the US design
- Inlet: a 30 A, 125 V NEMA TT-30 flanged inlet suits most vans. A 15 A or 20 A (5-15/5-20) inlet is an option for small systems. Use a 30 A → 15 A adapter at home, and never plug a 30 A van into a 15 A outlet without one. The NEC places the entrance on the road (driver's) side within 15 ft of the rear. The power cord must be at least 25 ft for a side entrance. The inlet must be labelled "DO NOT EXCEED CIRCUIT RATING" with its amp rating.
- Feeder: 10 AWG copper from the inlet to the panel for 30 A.
- Loss-of-ground device (GMI): the 2023 NEC replaced the old reverse-polarity indicator requirement with a loss-of-ground device for RVs with 30 A or 50 A service, and the 2026 NEC finalised it. Enforcement for certified manufacturers follows RVIA's adoption dates. It isn't something a DIY build is inspected against, but it is now the factory standard, so consider fitting one.
- Panelboard: a dead-front RV distribution panel with a 30 A main breaker (required where there are more than two branch circuits) and 15/20 A branch breakers. Article 551 asks for working space 24 in wide × 30 in deep in front of the panel, with an exception allowing 22 in. Plan the panel location early in a van.
- Neutral and ground kept separate: the neutral bar must be isolated from the panel case. Remove any bonding screw or strap. The ground bar is bonded to the case. The neutral-to-ground bond belongs at the campground service, or in the inverter while it is inverting, never in the van's panel.
- Chassis bond: the panel ground bar is bonded to the van chassis with an 8 AWG copper bonding conductor and solderless pressure connectors. The converter/charger case is also bonded to the frame with 8 AWG.
- GFCI: 15/20 A, 125 V receptacles must be GFCI-protected if they're outside, next to a bathroom basin, within 6 ft of a sink, or in the toilet or shower area. In a van almost every outlet is near the sink, so protect them all, for example with a GFCI receptacle first on the circuit.
- Branch circuits: 20 A circuits on 12 AWG copper, or 15 A on 14 AWG. Use wiring methods permitted by Article 551, protected where they pass through metal.
- Converter/charger: listed for RV use (UL 458). It's fed from its own breaker. Its DC output is fused at the busbar (F5).
- Inverter or inverter/charger (optional): must be listed for RV use (UL 458). Any transfer switch must be listed, and shore power and inverter output must never be connected together. An inverter/charger with an internal transfer switch and ground relay (for example the 120 V Victron MultiPlus) bonds neutral to ground only while inverting and opens that bond on shore power. GFCI-protect the outlets it feeds too.
US testing (NEC 551.60)
- Dielectric strength test on the 120 V wiring with switches closed: 900 V AC or 1,280 V DC for 1 minute, or 1,080 V AC or 1,530 V DC for 1 second. Do this before the DC is connected and with electronics disconnected. This is a job for an electrician with the right tester.
- Continuity of the bonding of all exposed metal and the chassis.
- Polarity check of every receptacle and device.
- Operational test of every GFCI and appliance, and of the loss-of-ground device if fitted.
- Then complete the 12 V checklist and crimp checks exactly as in sections 11 and 12.
16. Sources
- IET – Electrical installations in caravan/camping parks, caravans and motor caravans
- IET Wiring Matters – The impact of Amendment 4:2026
- Electrical Safety First – BS 7671 Amendment 4 pocket guide
- Tiny Build Electrics – BS 7671 Amendment 4: campervan, motorhome and cabin changes
- Tiny Build Electrics – Which RCD do you need for a campervan?
- Caravan and Motorhome Club – Hooking up to the mains
- EN 1648-2:2018 – Leisure accommodation vehicles, 12 V DC extra-low-voltage installations, Part 2: motor caravans (catalogue summary)
- Victron – Orion-Tr Smart non-isolated manual: installation, fuses and cable sizes
- Victron – Wiring Unlimited: DC wiring
- Victron – SmartSolar MPPT 100/30 and 100/50 manual: installation (battery fuse, connection order, PV earthing)
- Blue Sea Systems – MRBF terminal fuse specifications (interrupt rating)
- Littelfuse – MAXI 32 V fuse datasheet (interrupt rating 1,000 A)
- Blue Sea Systems – DC circuit protection (ABYC E-11 fuse location)
- Just Kampers Insurance – DVLA campervan conversion reclassification
- NEC Article 551 – Recreational vehicles (text summary)
- ANSI/RVIA LV-2020 – Standard for Low Voltage Systems in Conversion and Recreational Vehicles
- Lithionics – 2026 RVIA standards (NFPA 1192 2026, ANSI/RVIA DC 2025, NEC 2026; UL 1973/2054)
- RVIA – Grounding monitor interrupters on RVs
- The Van Guide – RVIA certification for van conversions
- Blue Sea Systems – ABYC conductor ampacity tables
- Victron Community – MultiPlus ground relay
- RV electrical code overview – NEC and UL 458
This guide is for a typical build, not a substitute for a site-specific design. OffGridVolts accepts no liability for installations based on it. Have the 230 V installation inspected, tested and certified by a competent electrician.
New to some of the terms? See the glossary. Not sure where to start? Try start here.