Home › Guides › DIY solar kit

Build a basic solar power kit: one panel, one battery, one inverter

A beginner's step-by-step guide to a small 12 V solar system: one 200 W panel (or a 37 V household panel), a 100 Ah lithium battery and a 600 W pure sine inverter. It concentrates on what makes a DIY system safe: fuses in the right place and properly crimped, tight connections.

By Michael Johnson · Updated 18 November 2026 · How we check our guides · Open the wiring diagram full size

Read this first. A 12 V battery won't give you a shock, but it is not harmless. A lithium battery can push more than 1,000 A into a short circuit, enough to weld a spanner and melt cable insulation in seconds. Most DIY solar fires don't come from the battery itself. They come from a missing or wrong fuse, or a bad connection that slowly overheats. Follow the fuse and crimping sections exactly, and this is a safe, simple project.

1. What you'll build

PartExampleWhy
Solar panel1 × 200 W "12 V" panel (Voc about 24 V, Isc about 10.5 A)Low voltage, so the whole system stays at extra-low voltage. Easy to handle and mount.
Charge controllerMPPT, 100 V input, 20 A output (e.g. Victron SmartSolar 100/20)Takes up to about 290 W of panel at 12 V, so there's room to add a second panel later.
Battery12.8 V 100 Ah LiFePO4 (1.28 kWh) with built-in BMS rated 100 ALight, long life, safe chemistry. The BMS protects the cells, but it is not a substitute for a fuse.
Inverter600 W pure sine wave, 12 V, with built-in sockets (ideally with a built-in RCD/GFCI)Runs normal mains appliances up to 600 W from its own sockets. It draws about 56 A from the battery at full power.
ProtectionBattery fuse 100 A, inverter fuse 80 A, controller fuse 25 A, battery isolator switch, PV isolatorSee Fuses.

What it can run: the battery stores about 1.2 kWh of usable energy. That's a 60 W laptop for about 18 hours, or a 50 W TV and LED lights for an evening. On a good summer day in the UK, the panel puts back roughly 0.6–1 kWh. In midwinter, expect only a fraction of that. Sunnier parts of the USA and Australia do much better. Allow for the inverter's own standby draw: 5–10 W even with nothing plugged in, or about 0.2 kWh a day, so switch it off when not needed. A fridge compressor can briefly draw 3–5 times its running power when it starts, so check the inverter's surge rating. To plan your own use, try the off-grid solar system calculator.

Kettles, heaters, hair dryers, microwaves and power tools above 600 W won't run on this system. Trying will trip the inverter, or overload the battery BMS. To run them you need a bigger system with heavier cables and fuses. See our 3 kW and 5 kW off-grid solar guide.

Option B: one 37 V "household" panel

UK electrical wholesalers and DIY stores mostly sell the large 400–445 W panels made for house roofs, not "12 V" panels. A typical 405–435 W, 108-cell panel has a Voc of about 37 V, Isc about 13.5–14 A, and Vmp about 31 V. One of these works very well on this 12 V kit, and roughly doubles the solar power, but it needs a bigger charge controller:

ItemOption A: 200 W "12 V" panelOption B: about 410 W, 37 V panel
Panel voltage (Voc)about 24 V (about 27 V on a frosty morning)about 37 V (about 41 V at −10 °C). Still extra-low voltage, so DIY is fine.
Panel current (Isc)about 10.5 Aabout 13.8 A
Charge controllerMPPT 100 V / 20 A (e.g. Victron SmartSolar 100/20, 290 W at 12 V)MPPT 100 V / 30 A, e.g. Victron SmartSolar MPPT 100/30: 100 V maximum PV voltage, 35 A maximum PV short-circuit current, 30 A charge, 440 W nominal at 12 V. Around £95 in the UK. Budget alternatives: EPEver Tracer 3210AN, Renogy Rover 30 A (both 100 V / 30 A). Check the datasheet for maximum PV voltage, maximum PV power at 12 V and maximum PV current.
Controller fuse F225 A40 A (30 A × 1.25; Victron recommends 35–40 A for the 100/30)
Controller cable C26 mm² (US 10 AWG)10 mm² (US 6 AWG): about 0.10 V drop over 1 m
Panel cable C16 mm² solar cable6 mm² solar cable: about 0.75 V (2.4%) over 10 m
PV isolator2-pole, ≥ 100 V DC, ≥ 16 A2-pole, ≥ 100 V DC, ≥ 20 A (1.25 × Isc = 17.3 A)
Size and weightabout 1.0 × 0.7 m, 10–12 kgabout 1.7 × 1.1 m, 20–22 kg. Needs a solid frame, and must be fixed to resist wind.
Energy on a good summer day (UK)roughly 0.6–1 kWhroughly 1.2–2 kWh, enough to fill the 100 Ah battery. Consider a second battery later.

Use an MPPT controller, not a cheap PWM one, with a 37 V panel. A PWM controller connects the panel straight to the battery, dragging it down to about 13–14 V. You would lose more than half of the panel's power. An MPPT controller converts the panel's 31 V down to battery voltage and keeps nearly all of it.

Adding a second 37 V panel later: two in series is about 82 V Voc on a cold morning, so a 100 V controller still accepts it. But a 30 A controller at 12 V is capped at about 440 W, so for two panels plan a bigger controller (e.g. 100/50), or move to a 24 V battery.

Why the inverter must be pure sine wave: inductive loads

Mains electricity is a smooth sine wave. A pure sine wave inverter makes the same smooth wave, typically with under 3–5% distortion. A cheaper modified sine wave inverter makes a stepped, blocky wave with roughly 15–30% distortion. Resistive loads like heaters, kettles and old filament bulbs don't mind the difference. Inductive loads do.

What an inductive load is: anything with a coil of wire around iron, mainly motors and transformers. The coil resists sudden changes in current, so a stepped wave makes it work harder. On a modified sine inverter, inductive loads typically:

Motors also need a big starting surge. A motor or compressor starting from rest can draw 3–7 times its running power for a fraction of a second up to a few seconds. Transformers draw a very large inrush for a few milliseconds when switched on. The inverter's surge rating, not just its continuous rating, has to cover this. Many 600 W pure sine inverters surge to about 1,000–1,200 W for a short time. Check the datasheet.

Inductive load (examples)TypeTypical running powerTypical start surgeOn this 600 W kit?
Fridge, freezer, dehumidifierCompressor (induction motor)60–150 W3–8× (often 600–1,000 W)Usually yes, with a good-surge inverter. Test it.
Water pump, pond pump, booster pumpInduction motor50–750 W3–7×Small pumps (under about 150 W) yes. Larger ones no.
Fans: desk, pedestal, extractorSmall induction motor20–60 W2–3×Yes
Power tools: drill, jigsaw, grinder, circular sawUniversal (brushed) motor300–1,200 W2–3× brieflyA small drill yes. Grinders and saws usually no.
Air compressorInduction or universal motor, starting under load750–1,500 W3–6×No
Microwave ovenTransformer (high-voltage) and fan motorInput 1,100–1,500 W for an 800 W ovenInrush on switch-onNo
Washing machine, tumble dryerMotor (plus a resistive heater)200–2,500 W2–4× (the motor)No (the heater alone is too big)
Air conditioner, heat pumpCompressor500–2,000 W3–6× (less with "inverter" models or a soft-start)No
Transformer-based equipment: older battery chargers, linear power supplies, toroidal audio amplifiers, ham radio linear PSUs, soldering stationsIron-core transformer20–500 WVery high inrush for a few msSmall ones yes
Fluorescent tubes with magnetic ballasts, metal-halide (HID) lampsBallast (inductor)20–150 WModestYes on pure sine. HID lamps can be damaged on modified sine.
Hair clippers, shavers, sewing machines, mixers, CPAP machinesSmall motors, some with electronic speed control10–150 WSmallYes on pure sine. They may run hot or erratically on modified sine.

The figures are typical ranges to plan with. The real numbers are on each appliance's rating plate or in its manual, or you can measure them with a plug-in power meter or clamp meter. To size the inverter for continuous and surge watts, use the inverter size calculator.

Watts are not VA. Inductive loads have a power factor below 1, so they draw more current (VA) than their watts suggest. A 100 W fridge might draw 150 VA. Some inverters are rated in VA, and their continuous watt rating is lower. Leave about 25% headroom on top of the running watts.

Tips for starting motors: start one motor at a time. Switch on the biggest motor first, with nothing else running. Inverter "power saving" or search modes can fail to wake for small motor loads, so turn that mode off if a fan or fridge won't start. Soft-start kits for compressors (especially air conditioners and fridges) can cut the surge a lot.

2. Will it run my stuff? Real sun data, month by month

Solar output changes enormously through the year, especially in the UK. These figures come from PVGIS, the European Commission's free solar database (version 5.3). It uses 19 years of satellite and weather data, including shading from the local horizon.

Step 1: add up your daily use (worked example)

AppliancePowerHours a dayEnergy a day
LED lights, 4 × 5 W20 W5100 Wh
Phone charging, 2 phones––30 Wh
Laptop50 W3150 Wh
Router or small radio10 W550 Wh
Inverter standby and losses––70 Wh
Total for Option A (200 W panel)400 Wh/day
Add: 12 V or small mains fridge (averaged over the day)––250 Wh
Add: TV, 50 W for 3 hours50 W3150 Wh
Total for Option B (37 V, about 410 W panel)800 Wh/day

To build your own list, use the power consumption calculator.

Step 2: what one kilowatt of panels makes each day, by month

Average kWh per day from 1 kWp of panels, tilted at about the latitude and facing the equator (south in the UK and USA, north in Australia), with 14% system losses. Multiply by your panel size: 0.2 for a 200 W panel, 0.41 for a 410 W panel.

Location (tilt)JanFebMarAprMayJunJulAugSepOctNovDecYear
London (50°)1.52.02.83.73.63.83.73.43.22.41.81.31014
Glasgow (55°)0.91.62.43.33.43.33.32.92.51.81.30.8841
Seattle WA (45°)1.72.53.33.84.03.84.44.43.92.91.91.51160
Phoenix AZ (35°)4.65.25.65.75.45.14.64.75.05.24.84.31829
Sydney (35°)4.54.44.24.13.93.33.84.44.94.84.64.61559
Melbourne (40°)4.84.84.33.62.82.52.83.34.14.54.54.71426

So a 200 W panel in London makes about 0.75 kWh a day in June but only about 0.27 kWh a day in December. That's a three-to-one difference. In Glasgow it's more than four-to-one.

Step 3: the whole system simulated, with the battery

PVGIS also simulates a complete off-grid system day by day: panel, battery and load. Each cell shows the average energy delivered per day (Wh) and, underneath, the percentage of days the battery ran flat. When it runs flat, the load is cut. These runs used a 1,280 Wh battery with 10% kept in reserve and PVGIS's standard evening-heavy load pattern.

Option A: 200 W panel, 400 Wh/day load

LocationJanFebMarAprMayJunJulAugSepOctNovDecYear
London223
81%
305
61%
381
21%
403
3%
396
2%
402
1%
400
0%
398
1%
394
1%
356
22%
287
63%
218
88%
29%
Glasgow141
97%
246
79%
352
40%
401
8%
399
1%
399
0%
400
0%
396
1%
373
10%
302
50%
214
86%
131
99%
39%
Seattle WA265
60%
353
32%
394
5%
404
1%
398
0%
402
0%
400
0%
399
0%
396
0%
378
9%
295
45%
234
71%
19%
Phoenix AZ400
0%
400
0%
400
0%
400
0%
400
0%
400
0%
400
0%
400
0%
400
0%
400
0%
399
0%
400
0%
0%
Sydney398
0%
400
0%
398
0%
400
0%
398
0%
397
1%
400
1%
403
0%
402
0%
400
0%
398
0%
402
0%
0%
Melbourne400
0%
398
0%
400
0%
396
0%
393
0%
386
11%
403
4%
407
0%
402
0%
401
0%
401
0%
399
0%
1%

Option B: about 410 W panel, 800 Wh/day load

LocationJanFebMarAprMayJunJulAugSepOctNovDecYear
London447
82%
580
66%
711
35%
785
8%
783
7%
793
4%
799
1%
789
4%
773
12%
686
40%
565
68%
443
87%
34%
Glasgow289
97%
482
81%
654
51%
770
18%
787
8%
791
5%
797
4%
780
9%
721
31%
581
61%
433
86%
269
99%
46%
Seattle WA505
65%
645
44%
751
15%
791
6%
794
1%
800
1%
799
0%
798
0%
787
4%
722
25%
566
56%
458
75%
24%
Phoenix AZ798
1%
799
1%
800
0%
800
0%
800
0%
800
0%
800
0%
800
0%
799
0%
800
0%
799
0%
797
2%
0%
Sydney794
1%
796
1%
790
3%
795
2%
791
2%
778
7%
795
3%
803
1%
802
1%
799
1%
795
0%
803
0%
2%
Melbourne799
0%
796
0%
800
0%
787
3%
775
11%
755
22%
773
14%
804
3%
802
1%
800
1%
801
0%
798
0%
5%
What the numbers say:
  • UK: both options cover their load from April to September (except Glasgow, where Option B still runs flat on 18–31% of days in April and September). From November to January the battery runs flat on most days. Plan to use less in winter, top up from a mains charger or generator, or add panels.
  • Seattle and similar northern US climates: similar to the UK, but slightly better.
  • Arizona, Sydney and Melbourne: a single panel covers these loads almost all year. Melbourne's Option B runs flat on about 1 day in 5 in June (22%).
  • Panels beat batteries in winter. A bigger battery doesn't help if the panel can't fill it. Adding panels (or a steeper tilt for winter) does.

Source: PVGIS 5.3 (European Commission JRC), PVcalc and off-grid (SHScalc) tools, queried 13 November 2026. UK locations use the PVGIS-SARAH3 database; US and Australian locations use PVGIS-ERA5. Treat results as long-term averages: a run of dull days can still flatten the battery in any month.

3. Choosing a battery

LiFePO4 (lithium iron phosphate)AGM / gel (sealed lead-acid)Flooded lead-acid
Usable energy from "100 Ah"About 90–100 AhAbout 50 Ah (to keep it healthy)About 50 Ah
Cycle life3,000–6,000+ cycles300–800 cycles500–1,200 cycles with maintenance
Weight (100 Ah)About 11–13 kgAbout 28–32 kgAbout 25–30 kg
Cold weatherMust not charge below 0 °C without a heater or low-temperature cut-offCharges in the cold (slowly)Charges in the cold, but can freeze when flat
VentilationNo gassingSmall amounts of gas if overchargedGives off hydrogen, so must be vented to outside
Best forThis guide's kit: almost always the best value over its lifeVery occasional use, or very cold unheated shedsNot recommended for beginners

LiFePO4 buying checklist

The 12 V side of this kit (panel, controller, battery and inverter input) is all extra-low voltage: under 120 V DC. A DIYer can legally build that in all three countries. The rules change the moment you touch mains (230 V or 120 V) wiring.

CountryOK to DIYNeeds a professional
UKAll the 12 V wiring. Plugging appliances into the inverter's own sockets.Wiring the inverter output into a building's fixed circuits, a consumer unit or new sockets. That's a BS 7671 installation that must be inspected, tested and certified. In a dwelling it must also be notified under Building Regulations: Part P in England and Wales (through a registered electrician or building control), or a building warrant in Scotland. Never connect it to a house that also has a mains supply without a proper changeover switch fitted by an electrician.
AustraliaExtra-low voltage work (up to 50 V AC / 120 V ripple-free DC), which covers the whole 12 V side and this single panel. Plugging appliances into the inverter's sockets.Any 230 V fixed wiring must be done by a licensed electrician, by law, and certified. A fixed battery system of 1 kWh or more, like this one, comes under AS/NZS 5139 (in its lowest voltage class, DVC-A, up to 60 V DC). Follow its rules on location, barriers and labels.
USAA portable or plug-in system like this is generally not "premises wiring". Plugging appliances into the inverter's sockets.A permanently installed system, or anything wired into a building's panel, comes under the NEC (Articles 690, 706, 710) and usually needs a permit. Check with your local building department (AHJ).

5. Wiring diagram

Basic DIY solar kit – wiring diagram 1 panel · 1 battery · 1 inverter · 12 V · every positive cable fused at the battery end Solar panel A: 200 W, Voc ≈ 24 V, Isc ≈ 10.5 A B: ≈ 410 W, Voc ≈ 37 V, Isc ≈ 13.8 A C1 6 mm² solar cable, MC4 PV isolator 2-pole DC switch / breaker MPPT charge controller A: 100/20 · B: 100/30 F2 25 A / 40 A A / B C2 6 / 10 mm² − to negative busbar 12 V POSITIVE BUSBAR / FUSED DISTRIBUTION BLOCK Battery isolator on/off switch, ≥ 100 A F1 100 A MRBF ≤ 150 mm from + terminal C3 25 mm² LiFePO4 battery 12.8 V 100 Ah internal BMS (100 A) Shunt (optional) NEGATIVE BUSBAR (all negatives) F3 80 A at the busbar Inverter 600 W pure sine, 12 V (built-in RCD / GFCI outlet) C4 16 mm² (≤ 1.5 m) chassis earth per manual Inverter socket plug-in appliances only never wired into house circuits F4 30 A DC loads 12 V fuse box (optional) − to neg. busbar The golden rules 1. Fuse every positive cable at the battery (source) end. 2. Fuse rating ≤ the cable's current rating. 3. Battery fuse within 150 mm of the + terminal. 4. Crimp lugs with the right tool and die – pull test each one. 5. Lug flat on the terminal – nothing in between, torqued. 6. Connect battery to the controller BEFORE the panel. 7. Cover the panel (or open its isolator) while wiring. 8. 230 V / 120 V only from the inverter's own socket. 9. Check every joint for heat after an hour at full load. 10. Isolator OFF for F2–F4. F1 stays live: battery − off first. Key 12 V positive 12 V negative 230 V / 120 V AC (inverter output) Optional
Everything connects to two busbars (or a fused distribution block). Every positive cable has a fuse at the end nearest the battery. F = fuse, C = cable (sizes in the cable sizes section).

6. Fuses: the most important part

What a fuse is for

A fuse protects the cable, not the gadget. If a cable gets chafed through and touches the metal frame, or a tool drops across two terminals, the battery will try to push hundreds or thousands of amps through it. Without a fuse, the cable glows red, the insulation melts and burns, and nothing stops it until something gives way. A correctly sized fuse in the right place blows in a fraction of a second.

The four rules

  1. Every positive cable connected to the battery gets a fuse. That means the battery itself, the inverter, the charge controller and the DC fuse box. No exceptions. "It's only a short cable" isn't an exception.
  2. Put the fuse at the battery end of the cable. The battery is where the fault current comes from. A fuse at the far end leaves the whole cable unprotected. The main battery fuse F1 should be within 150 mm (6 in) of the battery's + terminal, or bolted straight onto it with a terminal fuse holder.
  3. Size it between the load and the cable. The fuse must be bigger than the normal current (×1.25 for headroom), but no bigger than the cable can carry. If in doubt, use a bigger cable, never a bigger fuse.
  4. Use a fuse that can actually break the fault. Every fuse has an interrupt rating (AIC): the largest current it can safely stop. A lithium battery can deliver more than 1,000 A. On the battery terminal, use an MRBF terminal fuse (10,000 A at 14 V) or a Class T fuse (20,000 A). A small blade fuse or a cheap "car audio" ANL fuse there may arc instead of breaking the circuit.

The fuses in this kit

FuseWhereRatingTypeWhy that size
F1Battery + terminal, ≤150 mm100 AMRBF terminal fuse or Class TMatches the 100 A BMS. Protects the 25 mm² main cable.
F2Busbar, on the controller's positive cable25 A (Option B: 40 A)MIDI or MEGA, interrupt rating checked (see below)20 A controller × 1.25, on 6 mm² cable. Option B: 30 A controller, 40 A fuse on 10 mm². Check the controller manual.
F3Busbar, on the inverter's positive cable80 AMIDI or MEGA, interrupt rating checked (see below)600 W ÷ (12 V × 0.9) ≈ 56 A, × 1.25 = 70 A, so 80 A. 16 mm² cable. Check the inverter manual.
F4Busbar, on the DC fuse box feed (optional)30 AMIDI or MEGA, interrupt rating checked (see below)Feeds a small 12 V fuse box, which has its own blade fuse per circuit.
–Solar panelNone needed–One panel can't push more than its own Isc (about 10.5 A, or 13.8 A for a 37 V panel) into its own cable. Fuses only become necessary with 3 or more panels in parallel.
Check the interrupt rating of every fuse, not just F1. MIDI and MEGA fuses usually have a much lower interrupt rating (AIC) than an MRBF or Class T fuse. Some MEGA fuses are rated around 2,000 A at 32 V DC; MIDI and Maxi ratings are often lower. A short circuit on the busbar side can still be fed by the full battery fault current. Don't assume F1 will clear it first: whether a big upstream fuse protects a smaller one (called backup or series protection) is only reliable where the maker has tested and documented that exact combination. So before you buy:
  1. Find the battery's prospective short-circuit current from its datasheet, or ask the maker. Some LiFePO4 BMSs limit it; many batteries can deliver several thousand amps for a moment.
  2. Check each fuse's interrupt rating at your voltage (at 14 V DC or more) on its datasheet. If it's at least the battery's short-circuit current, that fuse is fine on its own.
  3. If it isn't, use fuses that are (MRBF or Class T for the branch circuits as well, or a fuse system whose maker states a rating high enough), or use a main fuse and branch fuse combination the maker documents as tested.
Blade and Maxi fuses (about 1,000 A interrupt rating) belong only in the 12 V fuse box, on small circuits after F4.

Common fuse mistakes

7. Good connections: crimps, lugs and terminals

A fuse can't save you from a bad connection. A loose, corroded or badly crimped joint has extra resistance. It gets hot while carrying normal current, so the fuse never blows. The heat makes the joint worse, which makes it hotter. That's how most "mystery" DIY solar fires start: in a terminal, not in the battery.

How much heat a bad joint gives off with the inverter running flat out at 56 A (heat = current² × resistance):

JointExtra resistanceHeat in the joint
Good hydraulic crimp, clean and torquedwell under 0.5 mΩunder 1.5 W (barely warm)
Poor crimp1 mΩ3 W
Loose battery terminal nut5 mΩ16 W (too hot to touch)
Corroded or hammer-crimped lug10 mΩ31 W, as much as a soldering iron, concentrated in one spot

Use the right tool for each cable

CableTerminalRight toolNever use
Battery, inverter and busbar cables (16–25 mm²)Tinned copper tube lug, matched to the cable size and the stud size (e.g. 25 mm² × M8)Hydraulic crimper with the hex die marked for that cable size. If you don't want to buy one, many suppliers will make cables up to length for you.Hammer crimpers, pliers, a vice, lugs made for a bigger cable
Controller and fuse box cables (4–6 mm²)Tube lugs, or pre-insulated crimps (yellow 4–6 mm²)Ratchet crimper with dies to matchCheap stamped "plier" crimpers
Fine-strand cable in screw terminals (controller, inverter)Bootlace ferruleFerrule ratchet crimperBare twisted strands, or ends tinned with solder
Solar panel cableMC4 connectors, both halves the same makeMC4 crimp tool with the right die, plus MC4 spannersMixing MC4 brands; pliers

Making a good crimp, step by step

  1. Cut the cable square with proper cable cutters.
  2. Strip exactly the depth of the lug barrel. Don't nick or cut any strands.
  3. Push the cable fully home. Copper should just show at the inspection hole, and the insulation should butt up to the barrel.
  4. Crimp with the die marked for that size. On long barrels, make two crimps.
  5. Inspect: an even hex shape, no cracks, no stray strands.
  6. Pull test: pull hard by hand. If the lug moves at all, cut it off and start again. Never re-crimp a bad one.
  7. Slide on adhesive-lined heat-shrink (red for positive, black for negative) and shrink it over the barrel and onto the insulation.

Bolting it up

8. Cable sizes

RefRunMax length (one way)CurrentMetricUSVoltage drop
C1Panel → isolator → controller10 m10 A (B: 13 A)6 mm² solar cable (H1Z2Z2-K)10 AWG PV wire≈ 0.57 V (2.9% of 20 V). B: ≈ 0.75 V (2.4% of 31 V)
C2Controller → busbar (via F2)1 m20 A (B: 30 A)6 mm² (B: 10 mm²)10 AWG, the largest the 100/20 terminals take (B: 6 AWG)≈ 0.12 V (0.9%). B: ≈ 0.10 V
C3Battery → F1 → isolator → busbar0.5 mup to 100 A25 mm²2 AWG≈ 0.07 V (0.5%)
C4Busbar → F3 → inverter1.5 m56 A16 mm²4 AWG≈ 0.18 V (1.4%)
–Busbar → F4 → 12 V fuse box2 mup to 30 A6 mm²8 AWG≈ 0.34 V at 30 A
–All negativesSame size as the matching positive cable, back to the negative busbar

Use fine-stranded copper cable rated for the job: tri-rated or welding cable for the 16–25 mm² runs, and solar cable for the panel. Keep the inverter cables as short as you can. The thick cables carry big currents at low voltage, so a few extra metres make a real difference.

9. Mounting the panel

Direction and tilt

UKUSAAustralia
FaceSouth (south-east to south-west loses only about 5–10%)SouthNorth
Tilt for all-year useAbout 35–40°About your latitude (25–45°)About your latitude (20–40°)
Tilt for the best winter output (off-grid)50–60°Latitude + 10–15°Latitude + 10–15°

For an off-grid system, winter output matters most, so tilt steeper than a grid-tied roof system would. A steep panel also sheds rain, snow and leaves better. The PVGIS figures in this guide use 50–55° in the UK and about the latitude elsewhere.

Shading

Fixing it securely

Cabling outdoors

10. Step-by-step build

  1. Plan the layout on a board: battery at the bottom, isolator and busbars above, then controller and inverter. Keep it in a dry spot with air around the inverter and controller.
  2. Mount everything before connecting any cables. Strap or clamp the battery down so it can't move.
  3. Make up all the cables to length, crimped, pull-tested and heat-shrunk, as in the good connections section.
  4. Fit the negatives, except the battery's own negative. Connect the shunt (if used) to the negative busbar, then the controller and inverter negatives to the busbar. Leave the cable from the battery's − terminal disconnected, with its lug taped or covered, until step 7. While it's off, nothing in the system is connected to the battery.
  5. Fit the positives with all the fuses in place: F1 at the battery, the isolator (switched OFF), the busbar, then F2, F3 and F4 to each device. With the battery negative off, none of this is live yet.
  6. Check everything twice: red to +, black to −, every fuse the right rating, every nut torqued, the isolator OFF, the inverter's own switch OFF.
  7. Connect the battery negative last. Use insulated tools, and keep the spanner away from the + terminal. If the inverter manual asks for it, pre-charge its capacitors through a resistor first, to avoid a spark. Then switch the battery isolator ON. The controller should now show battery voltage.
  8. Only now connect the solar panel. Cover the panel (or keep its isolator OFF), plug in the MC4s, then switch on. Never connect the panel to the controller before the battery.
  9. Switch on the inverter with nothing plugged in. Check that its display or LEDs are normal.
  10. Plug in a small load (a lamp), then bigger ones, while watching for warnings.
What the isolator does and doesn't make safe. Switching the battery isolator OFF disconnects the battery's feed to the busbars, F2–F4 and the devices. It does not by itself make them dead: the solar charge controller (powered by the panel in daylight), an inverter's internal capacitors, a mains charger or any other connected source can still put voltage on the busbar. Treat the busbar as dead only after you have isolated every supply and measured 0 V. The battery isolator also does not make F1 safe. F1 sits between the battery and the isolator, so its battery side, and the battery terminals, stay live whatever the switch is set to.
  • To change F2, F3 or F4: switch the battery isolator OFF and the solar PV isolator OFF, switch off and unplug any mains or generator charger, switch the inverter off and wait for its capacitors to discharge, then check with a meter that the busbar reads 0 V before touching it.
  • To change F1 or work on the battery terminals: switch the isolator OFF, then disconnect the battery negative at the battery first and cover its lug. Work with insulated tools, and refit the negative last. If your battery has a BMS on/off switch, turn it off as well.

11. Settings

12. Multimeter basics

A basic digital multimeter (about £20–40) and, ideally, a DC clamp meter are the two tools that make this system safe to check. Here's how to do each test the guide asks for.

TestMeter settingHowWhat's good
Battery voltageDC volts (V⎓), 20 V range or autoRed probe on +, black on −LiFePO4 at rest (no charge or load for an hour): 13.3–13.4 V is about 80–95%; 13.1–13.2 V about half; 12.8–12.9 V about 20%; below about 12.5 V nearly empty. The curve is very flat, so use a battery monitor for state of charge.
Polarity before fitting a fuseDC voltsRed on the cable you think is +, black on −A positive reading means correct. A minus sign means it's reversed: stop and fix it.
Panel open-circuit voltage (Voc)DC volts, 200 V rangeWith the PV isolator OFF, measure at the panel side of the isolatorClose to the panel's Voc (about 22–24 V for Option A, 35–40 V for Option B). It's higher in cold sun and lower in heat.
Continuity of a cableContinuity (beeper) or ohms, power OFFProbe each end of the same cableA beep, or under 1 Ω
No short between + and − busbarsOhms, battery disconnectedOne probe on each busbarNot 0 Ω. The reading may climb as capacitors in the inverter charge, which is normal.
Volt drop across a jointDC millivolts (mV), system running under heavy loadOne probe on the cable just before the lug, the other on the terminal or busbar under itAt about 56 A: under 10–15 mV is good. Remake anything above about 30 mV.
CurrentDC clamp meter (it must be DC-capable, Hall-effect type; many cheap clamp meters read AC only). Don't use the meter's 10 A socket.Clamp around one cable only, positive or negativeBelow the fuse rating, and roughly what you expect from the load

Never measure battery current by putting the multimeter's probes across the battery or the fuse with the meter on its amps setting. That's a direct short through the meter, which can explode its internal fuse or the meter itself. Use a clamp meter, or read the battery monitor.

13. Test it properly

  1. Fuse check: every fuse fitted matches the table in the fuses section, and none is missing.
  2. Polarity: measure each connection with a multimeter before fitting its fuse.
  3. Volt-drop test under load: run something close to 600 W. With the meter on millivolts, measure across each joint, from the cable to the lug and from the lug to the terminal. At 56 A a good joint reads under about 10–15 mV. Remake any joint above about 30 mV, or one well above the others.
  4. Heat check: after 30–60 minutes at full load, carefully feel each lug and fuse holder (or use an infrared thermometer). Cables and joints should be barely warm. A lug warmer than the cable either side of it is a bad joint.
  5. Re-check torque after a week, then every few months. Copper settles and connections loosen with temperature changes.

14. Where to put it, and what never to do

15. Troubleshooting chart

SymptomLikely causesWhat to check or do
Controller shows no solar inputPV isolator off. MC4 not fully clicked. Reversed polarity. Night or deep shade. A blown fuse if string fuses are fitted.Measure Voc at the isolator (meter section). Check MC4s and polarity. Check for shade at that time of day.
Solar input present, but little or no chargingBattery already full. Charge voltages set too low. BMS has stopped charging (cold or high cell). Controller fuse F2 blown. Thin or long cables.Check the controller's state (float / absorption / off) and the battery temperature. Check the F2 fuse and the controller's battery voltage reading against the meter.
Inverter beeps or shuts down when a load startsStart surge too high for the inverter. Low battery voltage. Cables too thin or too long, so the voltage sags. A bad joint.Measure the battery voltage at the inverter terminals while the load starts. A large drop compared with at the battery means cable or joint trouble. Check the surge rating against the inductive-load table.
Inverter runs light loads but trips on heavy onesThe BMS's current limit or surge limit is being reached. A loose joint heating up.Check the BMS app for over-current events. Do the millivolt test on every joint under load.
Battery suddenly reads 0 V, or everything goes deadThe BMS has shut off (low voltage, over-current, temperature). The main fuse F1 has blown.Check F1. With all loads off, charge or "wake" the battery as its manual describes. Find out why before switching back on.
A fuse keeps blowingA real overload, a short or chafed cable, or an inrush current.Never fit a bigger fuse. Disconnect the loads and check the cable for damage. Measure the actual current with a clamp meter.
A lug, fuse holder or terminal is warmA loose nut, a poor crimp, corrosion, or a lug the wrong size for the cable or stud.Switch off, then remake the joint (new lug if crimped badly), clean it, and torque it correctly. Re-test with the millivolt test.
Battery doesn't last as long as it used toLost capacity. The BMS is balancing a weak cell. Daily use has crept up. Winter.Compare a full-to-empty test with the rated capacity. Check the BMS cell voltages (a big spread means imbalance). Compare your use with the sun data tables.
Radio or TV interferenceInverter or controller noise, or long unscreened DC cables.Keep positive and negative cables together. Fit ferrite cores on the DC and AC leads. Earth the inverter case as its manual says. Pure sine inverters are much quieter than modified sine.

16. Maintenance schedule

WhenCheck
First weekRe-torque every bolted joint (copper and lugs settle). Do the heat check at full load again.
MonthlyLook over the cables and the panel for damage, chafing or animals chewing. Read the battery monitor or BMS app: cell voltages, cycles and temperature. Check the controller's history for low-charge days.
Every 3 monthsClean the panel with plain water and a soft brush (no detergent, no pressure washer). Check the MC4s are dry and fully latched. Check the fuse holders and terminal covers.
YearlyTorque check of every joint and the millivolt test under load. Capacity test of the battery. Update controller and inverter firmware. Check the panel fixings and frame after the winter storms. Test any RCD with its button.
Before winterSteepen the panel tilt if it's adjustable. Make sure the battery is somewhere above 0 °C, or that its low-temperature cut-off works. Plan a backup charge source.

17. Upgrade path

18. Approximate costs

These are typical retail price ranges at November 2026, rounded, for budget planning only. Prices vary a lot, so check current prices.

ItemUK (£)USA ($)Australia (A$)
Panel: Option A 200 W / Option B about 410 W90–180 / 90–160120–220 / 120–220150–300 / 150–300
MPPT controller: 100/20 / 100/3070–110 / 95–14090–140 / 120–170140–220 / 180–260
LiFePO4 battery, 12.8 V 100 Ah200–450200–500350–800
Inverter, 600 W pure sine80–25090–300150–450
Fuses, holders, isolators and busbars80–160100–200150–300
Cable, lugs, heat-shrink, glands60–12070–150100–220
Tools: hydraulic crimper, ratchet crimpers, MC4 tool, multimeter, torque wrench80–200100–250150–350
Mounting rails or frame40–15050–20080–300
Typical totalabout 700–1,650about 850–1,900about 1,300–3,000

19. Printable checklists and labels

Before you switch on

  1. ☐ Every positive cable has a fuse at the battery end: F1 100 A, F2 25/40 A, F3 80 A, F4 30 A.
  2. ☐ F1 is within 150 mm of the battery + terminal, or mounted on it.
  3. ☐ Every fuse rating is at or below its cable's rating.
  4. ☐ Every fuse's interrupt rating is at least the battery's short-circuit current (or a documented tested combination).
  5. ☐ Every crimp was made with the correct tool and die, inspected and pull-tested.
  6. ☐ Every lug sits flat with nothing under it, is torqued to spec and paint-marked.
  7. ☐ Polarity is checked with a meter on every cable before its fuse goes in.
  8. ☐ No short between the + and − busbars (battery disconnected).
  9. ☐ The battery is clamped down, its terminals covered, and it's in a frost-free, ventilated, non-sleeping area.
  10. ☐ The controller is set to the LiFePO4 profile or the maker's voltages.
  11. ☐ The battery is connected to the controller before the panel.
  12. ☐ The inverter output is used only through its own sockets, with no connection to building wiring.
  13. ☐ A smoke alarm and a CO₂ or powder extinguisher are nearby.

Fuse schedule card (stick inside the enclosure lid)

FuseCircuitRatingTypeCable
F1Battery main100 AMRBF / Class T25 mm²
F2Solar controller25 A (B: 40 A)MIDI / MEGA6 mm² (B: 10 mm²)
F3Inverter80 AMIDI / MEGA16 mm²
F412 V fuse box30 AMIDI / MEGA6 mm²

Suggested labels

⚠ BATTERY ISOLATOR
Battery feed only: also open the PV isolator and check the busbar reads 0 V before working on F2–F4. F1 stays live: disconnect the battery negative first.
⚠ SOLAR DC – LIVE IN DAYLIGHT
Open the PV isolator before disconnecting
⚠ 12 V LITHIUM BATTERY
High short-circuit current. Insulated tools only.
⚠ INVERTER OUTPUT 230 V AC
Plug-in use only – not connected to building wiring

US readers: use "120 V AC" on the inverter label. Australian readers: battery systems covered by AS/NZS 5139 have their own mandatory signs. Use those in place of, or as well as, these.

20. Frequently asked questions

Do I really need a fuse if my battery has a BMS?

Yes. A BMS protects the battery's cells, and many can't safely interrupt a dead short. The fuse protects the cables. Use both.

Can I connect a solar panel straight to the battery?

No. Without a charge controller the battery will be overcharged, and a lithium battery's BMS would have to cut off repeatedly. Always use a controller.

Can I use a 37 V house solar panel on a 12 V battery?

Yes, with an MPPT controller rated at 100 V input (such as a 100/30). A cheap PWM controller would waste more than half the power. See Option B.

What size fuse do I need for a 600 W inverter?

At 12 V it draws about 56 A at full power, so use an 80 A fuse at the battery or busbar end, with 16 mm² cable. Always check the inverter manual's recommendation.

How far can the fuse be from the battery?

As close as practical, and no more than about 150 mm (6 in) in this guide. The US RV low-voltage standard (ANSI/RVIA LV) allows up to 18 in (457 mm) from the source; the marine standard ABYC E-11 uses 7 in. The cable between the battery and the fuse is unprotected.

Can I run a fridge from a 600 W inverter?

Usually yes, if it's a pure sine inverter with a good surge rating. A fridge compressor can draw 3–8 times its running power for a moment. Test it before relying on it.

Can I plug the inverter into my house wiring?

No. Back-feeding a building through a socket ("suicide lead") can kill you or a utility worker, and it's illegal. Connecting an inverter to building circuits needs a qualified electrician and proper changeover equipment.

Why does my crimp need a special tool?

Because a poor crimp has extra resistance and heats up under load without blowing a fuse. That's a common cause of DIY solar fires. A hydraulic crimper with the correct die makes a cold-welded joint that stays cool.

How much will it produce in winter?

In London, a 200 W panel averages about 0.27 kWh a day in December, against about 0.75 kWh in June. In Glasgow it's less; in Sydney or Arizona much more. See the sun data section for every month.

21. Shopping list

ItemQtySpecification
Solar panel1200 W "12 V" (Voc about 24 V), or Option B: about 410 W household panel (Voc about 37 V). With mounting brackets.
MPPT charge controller1100 V / 20 A (Option B: 100 V / 30 A, e.g. Victron SmartSolar 100/30)
LiFePO4 battery112.8 V 100 Ah, BMS ≥ 100 A, low-temperature charge protection
Inverter112 V 600 W pure sine, ideally with RCD/GFCI outlets
Fuses and holders1 setMRBF 100 A + terminal fuse block (or Class T 100 A + holder). MIDI/MEGA 80 A, 25 A (Option B: 40 A) and 30 A with holders.
Battery isolator switch1≥ 100 A continuous, DC rated
PV isolator12-pole DC switch or breaker, ≥ 100 V DC (matching the controller), ≥ 16 A (Option B: ≥ 20 A)
Busbars2Positive (or fused distribution block) and negative, with M8 studs
Cable–25 mm² and 16 mm² (red and black), 6 mm² (red and black), 6 mm² solar cable with MC4 extension leads
Terminals–Tinned tube lugs to suit each cable and stud, bootlace ferrules, adhesive heat-shrink in red and black
Tools–Hydraulic lug crimper (or have the big cables made up), ratchet crimper, ferrule crimper, MC4 crimp tool, cable cutters, torque wrench, multimeter
Optional–Battery monitor shunt, 12 V blade fuse box, plug-in RCD, smoke alarm, fire extinguisher

22. Check your own numbers

23. Sources

  1. European Commission JRC – PVGIS 5.3 (monthly PV and off-grid simulations)
  2. Samlex – Pure sine wave versus modified sine wave inverters
  3. Edecoa – Modified vs pure sine wave: effects on inductive loads
  4. Sterling Power – Inverters DC–AC
  5. Victron SmartSolar MPPT 100/30 specifications (100 V, 35 A Isc, 440 W at 12 V)
  6. Example UK 405 W 108-cell panel (Voc 37.23 V)
  7. Victron – Wiring Unlimited: DC wiring, cables, fuses and connections
  8. Blue Sea Systems – MRBF terminal fuse (10,000 A interrupt rating at 14 V)
  9. Littelfuse – MAXI fuse datasheet (1,000 A interrupt rating)
  10. Blue Sea Systems – DC main overcurrent protection (ABYC fuse placement)
  11. SolarQuotes – What electrical work you can legally do yourself in Australia
  12. ANSI/RVIA LV – low-voltage systems standard (fuse location, splice pull tests)

This guide covers a small plug-in system. It isn't a design for wiring into a building's mains installation; that work needs a qualified electrician. OffGridVolts accepts no liability for systems built from it. Always follow the manuals for the parts you buy.