Grid-tied solar and home batteries: sizing, export, backup and rules
How home solar and batteries work alongside the grid: inverter types, sizing for your bills, whether a battery pays, backup in a power cut, export payments, time-of-use tariffs, plug-in solar, and the connection rules, standards and incentives in the UK, USA and Australia in 2026.
By Michael Johnson · Updated 17 November 2026 · How we check our guides
Most solar in the UK, USA and Australia is grid-tied: the panels and battery work alongside the mains supply rather than replacing it. This guide covers how these systems work, how to size panels and batteries for your bills rather than for independence, what you're paid for exports, how backup in a power cut really works, and the connection rules, standards and incentives in each country as they stand in late 2026.
1. How a grid-tied system works
During the day, the panels make DC electricity. The inverter turns it into AC at grid voltage and frequency and feeds it into your consumer unit (switchboard). Your home uses that power first. If the panels make more than you're using, the surplus either charges a battery or flows out through the meter to the grid. At night or on dull days, you draw from the battery and then from the grid as usual.
The grid acts as an infinitely large, imperfect battery: it always takes your surplus and always fills the gap, but it usually pays far less for exported power than it charges for imported power. That price gap is what drives most decisions in this guide.
2. Inverter types
| Type | How it works | Good for | Watch out for |
|---|---|---|---|
| String inverter | Panels wired in series strings to one central inverter | Simple, unshaded roofs; lowest cost per watt | Shade on one panel pulls down the whole string unless optimisers are fitted |
| String + optimisers | A small DC converter behind each panel | Partly shaded or multi-direction roofs; panel-level monitoring | More electronics on the roof |
| Microinverters | A small inverter behind each panel (or pair) | Complex roofs, small arrays, easy expansion; AC on the roof (meets US rapid-shutdown rules) | Higher cost; batteries must be AC-coupled |
| Hybrid inverter | Panels, battery and grid all on one inverter | New installs with a battery now or later; most efficient battery charging from solar | Battery must be compatible with that inverter brand |
| AC-coupled battery | A battery with its own inverter, added to an existing system | Retrofitting a battery without touching the existing solar | Slightly lower round-trip efficiency (two conversions) |
3. Sizing the panels
Off-grid systems are sized for the worst month. Grid-tied systems are sized for the best return, which usually means filling the roof you have, within the connection limits in section 8.
| Location | Typical yield per kWp per year | 4 kWp system | 6 kWp system |
|---|---|---|---|
| Scotland, northern England | 750–850 kWh | 3,000–3,400 kWh | 4,500–5,100 kWh |
| Southern England | 900–1,050 kWh | 3,600–4,200 kWh | 5,400–6,300 kWh |
| US north-east / Pacific north-west | 1,100–1,300 kWh | 4,400–5,200 kWh | 6,600–7,800 kWh |
| US south-west, California | 1,500–1,750 kWh | 6,000–7,000 kWh | 9,000–10,500 kWh |
| Melbourne, Hobart | 1,200–1,350 kWh | 4,800–5,400 kWh | 7,200–8,100 kWh |
| Sydney, Perth, Brisbane, Adelaide | 1,400–1,600 kWh | 5,600–6,400 kWh | 8,400–9,600 kWh |
Figures are for a well-oriented, unshaded roof. East–west roofs give about 10–20% less in total but spread generation across the day, which suits self-consumption. Work out your own figure with the solar panel output calculator and how many panels fit with the roof fit calculator.
Self-consumption is what saves money
Every kWh you use yourself saves the full import price. Every kWh you export earns the (much lower) export rate. Without a battery, a typical home uses 25–40% of its solar directly; the rest is exported. A battery, a hot water diverter, an EV charger or a heat pump running in the day can raise that to 60–80%.
4. Is a battery worth it?
A battery stores midday surplus for the evening, and can also charge from cheap off-peak grid power. Whether it pays back depends on the gap between your import and export prices, your evening use, and in Australia the federal discount.
| Household | Typical evening/night use | Useful battery size |
|---|---|---|
| 1–2 people, gas heating | 3–5 kWh | 5 kWh |
| Family, gas heating | 6–9 kWh | 8–10 kWh |
| Family with heat pump or EV | 10–20 kWh | 10–15 kWh plus off-peak charging |
| All-electric, large home | 20 kWh+ | 15–25 kWh, or two batteries |
- Don't oversize. A battery that never empties overnight in winter and never fills in summer is wasted money. Size to your typical evening use, not your worst day.
- Cycle life: LiFePO4 home batteries typically last 6,000+ cycles or a 10-year warranty with a guaranteed 60–70% capacity at the end. Work out the cost per stored kWh with the battery cost per cycle calculator.
- Round-trip losses are about 10% (DC-coupled) to 15% (AC-coupled).
- Backup is a reason in itself where outages are common, even if the numbers alone don't pay back. Size it with the home backup battery calculator.
Batteries must be installed to the relevant fire-safety rules: in Australia AS/NZS 5139 restricts locations (not in habitable rooms, under stairs or in escape routes); in the UK, PAS 63100 (2024) gives installation guidance for home battery systems, including fire separation from escape routes; in the US, NFPA 855 and the IRC/IFC limit aggregate energy storage in garages and dwellings and require listing to UL 9540. See the lithium battery safety guide.
5. Backup in a power cut
Out of the box, most grid-tied systems, with or without a battery, shut down in a power cut. To keep running you need:
- An inverter with a backup (EPS/UPS) output or a separate backup gateway, which
- isolates your home or a backup circuit from the grid with an approved transfer relay or switch, then
- forms its own grid for the backed-up circuits from the battery and panels.
| Backup type | What stays on | Switch-over |
|---|---|---|
| EPS socket on the inverter | One or two sockets you plug into | Manual or a few seconds |
| Essential-loads circuit | Fridge, lights, router, boiler or furnace controls | Automatic, under a second to a few seconds |
| Whole-home gateway | Everything, within the inverter's power limit | Automatic, usually seamless |
Big loads (electric showers, ovens, heat pumps, central air) can exceed a home inverter's output; most installers put them outside the backup circuit or lock them out. For longer cuts, pair the battery with a generator; see the home backup power guide.
6. Getting paid for exports
UK: Smart Export Guarantee (SEG)
- Larger electricity suppliers must offer at least one export tariff to small generators. Rates and terms are set by each supplier; they range from a few pence to over 15p per kWh on some time-of-use deals.
- You need an export-capable smart meter and, for solar, an MCS-certified installation (or equivalent). You don't have to take the SEG tariff from your import supplier.
- Batteries are allowed, and some tariffs pay for exporting stored power at peak times.
USA: net metering and net billing
- Rules are set by each state and utility. Under net metering, exports earn bill credits at or near the retail rate. Under net billing, they earn a lower, often time-varying rate.
- California moved new customers to its Net Billing Tariff (often called NEM 3.0) from April 2023, with export credits based on avoided cost and much lower than retail, which pushed most new installs to include a battery.
- Check your state's rules on DSIRE and your utility's interconnection pages before signing.
Australia: feed-in tariffs
- Retailers set feed-in tariffs, often a few cents per kWh, with state regulators setting minimums or benchmarks in some states (for example Victoria's Essential Services Commission).
- Many networks now limit exports at the busiest solar times (often 5 kW per phase, less in constrained areas) or use flexible exports that vary the limit through the day.
- Some retailers charge for exports at midday under newer two-way tariffs, and pay more in the evening peak. A battery shifts exports to the evening.
7. Time-of-use tariffs and load shifting
With import prices that change through the day, the cheapest strategy is often:
- Run dishwasher, washing machine, hot water and EV charging when the sun is out (or on the cheap overnight rate).
- Charge the battery overnight on a cheap rate in winter, when solar is low.
- Use the battery through the evening peak.
- Export at peak times if your export tariff pays more then.
A solar diverter sends surplus to an immersion heater instead of exporting it. It pays where export rates are low and you heat water electrically. Compare fuels with the heating fuel cost calculator.
8. Connection rules and standards by country
United Kingdom
- Engineering Recommendation G98: small, type-tested inverters up to 16 A per phase (about 3.68 kW single-phase) can be connected first and the Distribution Network Operator (DNO) notified within 28 days.
- G99: anything larger, including solar plus battery where the combined inverter capacity exceeds 16 A per phase unless export is limited, needs the DNO's approval before connection. Export limiting is often used to stay within network limits.
- Wiring: BS 7671 (Section 712 for PV, Chapter 82 for prosumer installations, Section 551 for generating sets). In England and Wales the work is notifiable under Building Regulations Part P, and roof work must meet structural and fire rules.
- MCS certification is needed for the SEG and is the usual quality mark. The installer should register the system and give you an MCS certificate.
- Planning: panels on most homes are permitted development in England, with limits on protrusion, listed buildings and conservation areas; the rules were updated in August 2026. Check the Planning Portal or your council.
United States
- NEC Article 690 covers PV systems, 705 interconnection, and 706 energy storage. Most jurisdictions need a permit and inspection, and the utility needs an interconnection agreement and permission to operate (PTO) before you switch on.
- The 120% rule (NEC 705.12): when the inverter feeds a breaker on the main panel, 125% of the inverter's output current plus the main breaker rating may not exceed 120% of the busbar rating. A 200 A panel with a 200 A main can take a 40 A backfeed breaker, so an inverter of up to 32 A output. Larger systems need a supply-side connection, a smaller main breaker or a new panel.
- Rapid shutdown (NEC 690.12): roof-mounted PV must reduce conductor voltages within 30 seconds when the system is switched off, so firefighters are safe. Microinverters or optimisers usually meet it.
- Equipment must be listed: inverters to UL 1741 (with SA/SB grid-support functions under IEEE 1547), batteries and systems to UL 9540, cells to UL 9540A testing.
Australia
- AS/NZS 4777.1:2024 covers installation of inverter systems connected to the grid, and AS/NZS 4777.2 the inverter's grid-protection settings. The 2024 edition limits single-phase systems to 30 kVA and requires an aggregation board where there are more than two inverters.
- AS/NZS 5033 covers the PV array, AS/NZS 5139 battery installations, and AS/NZS 3000 the wiring.
- All grid-connected work must be done by a licensed electrician, with network approval before connection. For STCs and the battery discount, the designer and installer must be accredited by Solar Accreditation Australia and the products on the Clean Energy Council approved lists.
- Voltage rise from the inverter to the point of supply must stay within the limit set in AS/NZS 4777.1; check yours with the voltage rise calculator.
9. Plug-in (balcony) solar
From 27 August 2026, plug-in solar became legal to buy and connect yourself in Great Britain. Key points:
- The microinverter's AC output is capped at 800 W, with up to about 2,000 W of panels behind it.
- It must be a complete kit that meets the government's interim product specification and appears on the ENA G98 type-test register.
- It plugs into a fixed BS 1363 socket, never an extension lead or adaptor.
- You still notify your DNO under G98 within 28 days.
- Plug-in systems can't currently get SEG payments, because they aren't MCS-installed. Plug-in batteries aren't covered.
- Tenants can ask their landlord for permission, who can't unreasonably refuse under the Renters' Rights Act 2025.
An 800 W kit typically saves £80–£150 a year if you use most of what it makes. In the USA, plug-in solar is not generally allowed under the NEC, though Utah passed a law in 2025 allowing small portable systems and other states are considering it. In Australia, plug-in solar connected through a power point is not permitted; all grid connection must be by a licensed electrician.
10. Incentives, grants and tax in 2026
| Country | Scheme | What it gives |
|---|---|---|
| UK | 0% VAT on energy-saving materials | Solar panels and batteries installed in homes are zero-rated until March 2027 (Great Britain); batteries retrofitted to existing solar also qualify |
| UK | ECO4 / Great British Insulation Scheme / local grants | Funded solar for some low-income or fuel-poor households; schemes change frequently |
| UK (Scotland) | Home Energy Scotland loans | Interest-free loans for solar and batteries |
| USA | Residential Clean Energy Credit (25D) | Ended: not allowed for installations completed after 31 December 2025 |
| USA | State and utility rebates, SRECs, property tax exemptions | Vary widely; search DSIRE for your state |
| Australia | Small-scale Renewable Energy Scheme (STCs) | Upfront discount on solar panels, declining each year until the scheme ends in 2030 |
| Australia | Cheaper Home Batteries Program | From 1 July 2025: about 30% off eligible batteries via STCs. From 1 May 2026, the discount is tiered by size (full rate to 14 kWh, 60% for 14–28 kWh, 15% for 28–50 kWh) and falls every six months |
| Australia | State schemes | For example, interest-free loans and VPP incentives in some states |
Incentives change often. Check the official scheme pages in the sources before you sign.
11. Getting quotes: what to ask
- Get at least three quotes from certified installers (MCS in the UK, NABCEP-certified or state-licensed in the US, SAA-accredited in Australia).
- Ask for the estimated annual generation, self-consumption and savings, and the assumptions behind them (shading, tariff, usage).
- Check the brands and warranties: panels (product 10–25 years, performance 25–30 years), inverter (5–12 years, extendable), battery (usually 10 years with a capacity guarantee), and workmanship.
- Ask who handles the DNO/utility/network application and how long it takes.
- For a battery: what backup does it give, which circuits, and can it charge on cheap overnight rates?
- Avoid high-pressure sales, "free solar" leases you don't understand, and quotes that are well below the others.
12. Monitoring and maintenance
- Use the inverter app to compare monthly output with the estimate. A sudden 20% drop usually means a fault, shading or a tripped isolator.
- Panels mostly self-clean in rain; clean them only if very dirty, from the ground with a soft brush and water, never by climbing on the roof.
- Check for birds nesting under panels; mesh guards stop it.
- Have an electrician inspect the system every 4–5 years, including DC isolators and connectors.
- Inverters are the part most likely to fail; budget for a replacement once in the system's life.
13. Frequently asked questions
Will my solar panels work in a power cut?
Not unless the system has a backup output or gateway. Grid-tied inverters must shut down when the grid fails so they can't feed power into lines being repaired. A hybrid inverter with a battery and backup circuit, or a whole-home gateway, can keep chosen circuits running.
Do I need permission to connect solar panels to the grid in the UK?
Systems up to 16 A per phase (about 3.68 kW on a single-phase supply) can be connected under G98 and the DNO notified within 28 days. Larger systems, or solar plus a battery above that limit, need G99 approval from the DNO before connection.
Is plug-in solar legal in the UK?
Yes, in Great Britain from 27 August 2026, for approved kits up to 800 W AC that plug into a standard fixed socket. You must still notify your DNO under G98.
Is there still a federal solar tax credit in the US?
No. The Residential Clean Energy Credit (Section 25D) does not apply to systems whose installation was completed after 31 December 2025. State and utility incentives may still be available.
How much is the Australian battery rebate?
The federal Cheaper Home Batteries Program gives a discount through STCs on eligible batteries installed with solar. From 1 May 2026 it's tiered by battery size and falls every six months, so the dollar value depends on the battery size and installation date.
What size battery do I need with solar?
Enough to cover your typical evening and overnight use: often 5 kWh for a small household and 8–13 kWh for a family. Larger batteries make sense with an EV, a heat pump, frequent power cuts or time-of-use tariffs.
14. Sources
- GOV.UK, Smart Export Guarantee: gov.uk
- Energy Saving Trust, Smart Export Guarantee: energysavingtrust.org.uk
- Fuse Energy, plug-in solar legislation from 27 August 2026: fuseenergy.com
- Planning Portal, changes to permitted development for domestic solar (August 2026): planningportal.co.uk
- IRS, expiring clean energy tax incentives (25D and 25C): irs.gov bulletin
- California Public Utilities Commission, Net Billing Tariff: cpuc.ca.gov
- NYSERDA, the 120% rule fact sheet: nyserda.ny.gov
- Clean Energy Regulator, changes to the Cheaper Home Batteries Program: cer.gov.au
- CHOICE, solar home battery rebate changes: choice.com.au
- Standards Australia, what's new in AS/NZS 4777.1:2024: standards.org.au
- Energy Networks Australia, changes to inverter installation standards: energynetworks.com.au