Insulation decides how warm a van, horsebox, caravan or tiny house stays in winter, how cool it stays in summer, how much diesel or battery the heater uses, and whether you wake up to dripping walls. This guide compares the materials, explains vapour barriers and condensation (the part most people get wrong), shows where heat really escapes, and gives a layer-by-layer method for walls, roof, floor and windows.
1. Where the heat goes
In an uninsulated panel van at 0 °C outside and 20 °C inside, heat loss can exceed 2 kW. Good insulation cuts it to 400–800 W. The biggest losses, roughly in order:
- Windows and the cab: single glazing and the uninsulated cab can be a third or more of the total.
- Thermal bridges: steel ribs and pillars that connect the cold skin to the inside.
- Air leaks and ventilation: draughts round doors and through the floor.
- Roof, walls and floor: in that order, because warm air rises.
2. Insulation materials compared
| Material | Thermal conductivity (λ, W/mK) | R per 25 mm (m²K/W) | Pros | Cons |
|---|---|---|---|---|
| PIR / polyiso board (Celotex, Kingspan) | 0.022 | 1.14 | Best performance per thickness; foil faces act as a vapour barrier | Rigid, hard to fit curves; gaps must be taped or foamed |
| XPS board | 0.029–0.034 | 0.74–0.86 | Tough, moisture resistant; good for floors | Rigid; lower R than PIR |
| Closed-cell rubber foam (Armaflex type) | 0.033–0.036 | 0.69–0.76 | Self-adhesive, follows curves, acts as its own vapour barrier, damps sound | Expensive; heavy for its R-value |
| Sheep's wool | 0.035–0.040 | 0.63–0.71 | Fills cavities, handles moisture well, natural, no itch | Needs good ventilation/vapour control; check moth treatment |
| Polyester / recycled PET wool | 0.035–0.040 | 0.63–0.71 | Fills cavities, doesn't absorb water, no itch | Compresses if packed too tight |
| Thinsulate (automotive) | About 0.035–0.040 | About 0.6–0.7 | Light, hydrophobic, sound damping, easy to fit | Expensive |
| Spray foam (closed-cell) | 0.022–0.028 | 0.9–1.1 | Seals every gap; adds stiffness | Messy, hard to undo, can trap water if poorly applied; professional job |
| Mineral wool / glass fibre | 0.032–0.044 | 0.57–0.78 | Cheap | Holds water and sags with vibration; not recommended for vehicles |
| Foil bubble wrap ("reflective insulation") | Very low R on its own | About 0.1–0.2 | Cheap; reflective only with an air gap | Little insulation value: use as a radiant layer, not instead of insulation |
λ values are typical manufacturer figures. US R-value per inch ≈ 0.144 ÷ λ; for example PIR (λ 0.022) ≈ R-6.5 per inch.
3. Condensation and vapour control
Each person breathes out about 0.5–1 litre of water a day; cooking, showering and drying clothes add more, and gas heaters without a flue add a lot. When that moist air reaches a surface colder than its dew point, water condenses. Inside a wall, that means rust, rot and mould you can't see.
- Stop vapour getting into the wall with a continuous vapour control layer (VCL) on the warm (inside) face of the insulation: foil-faced PIR with taped joints, closed-cell foam, or a sheet membrane, sealed at edges and penetrations.
- Never put a second vapour barrier on the cold side without care: in a metal vehicle the steel skin is already impermeable, so anything that gets in can't get out. Keep the insulation tight to the skin (no air gaps where moist air can circulate) or use materials that tolerate moisture, such as closed-cell foam and wool.
- Remove moisture at the source: a roof vent fan when cooking, a lid on pans, a vented diesel heater (it adds dry air), and never an unflued gas heater.
- Keep it warm: a well-insulated, evenly heated interior has fewer cold spots for condensation.
- Some builders choose a "breathable" approach with wool and no membrane, relying on ventilation to dry the wall. It works if ventilation is good; either way, avoid trapped, uninsulated air pockets against the steel.
4. Layer by layer: walls, roof and floor
- Prepare: remove all rust, treat bare metal, and fit sound deadening (see section 8).
- Walls: fit closed-cell foam or cut PIR to the flat panels, bonded tight to the skin; fill deep cavities with wool or polyester; cover ribs (section 5).
- Roof: the most important surface. 25–50 mm of PIR or 20–30 mm of closed-cell foam, tight to the skin, joints taped.
- Floor: 15–25 mm of XPS or PIR between battens, with a plywood floor on top. Rubber or vinyl flooring finishes it.
- Vapour control: tape all foil joints with foil tape, or fit a membrane over the inside, taped to the edges and around every cable and fixing.
- Lining: ply, tongue-and-groove, carpet lining or panels, fixed with gaps for cables planned in advance (see the campervan wiring guide).
| Surface | Typical build-up (good) | U-value (approx.) |
|---|---|---|
| Wall | Steel + 19 mm closed-cell foam + 25 mm PET wool in cavities + VCL + 6 mm ply | 0.8–1.2 W/m²K (allowing for ribs) |
| Roof | Steel + 40 mm PIR (taped) + 6 mm ply | 0.5–0.8 W/m²K |
| Floor | Steel + 20 mm XPS + 12 mm ply + vinyl | 1.0–1.3 W/m²K |
| Uninsulated steel panel | – | 5–6 W/m²K |
Convert between U-values and R-values with the U-value to R-value converter.
5. Thermal bridges: the metal ribs
- The steel ribs, pillars and wheel arches conduct heat straight through. They're also where condensation appears first.
- Cover every rib with at least 6–10 mm of closed-cell foam before fitting battens or panels.
- Fix battens to ribs with plastic or rubber spacers rather than directly to bare metal.
- Fill rib cavities loosely with wool or polyester (don't pack them too tight).
6. Windows, doors and the cab
- Double-glazed acrylic windows (as in caravans) are far better than single-glazed glass.
- Insulated window covers (for example quilted silver screens) for the cab and windows make a bigger difference than another 10 mm of wall insulation. Fit them outside the glass in winter to stop condensation on the inside.
- A thermal curtain or insulated bulkhead between cab and living area cuts the cab's losses dramatically.
- Insulate and seal door cards and fit good seals to sliding doors.
7. Ventilation: the other half
- Fit a roof fan (extract) and a low-level inlet so moist air leaves and fresh air enters. Run the fan while cooking.
- Fixed ventilation is required for gas appliances. Never block it.
- A diesel heater adds dry, warm air from outside and removes the combustion products outside, which helps dry the interior. See the diesel heater guide.
- Crack a window or vent overnight, even in winter.
8. Sound deadening
- Butyl damping mats (Dynamat type) on 25–50% of large flat panels stop drumming; full coverage adds weight with little benefit.
- Closed-cell foam and Thinsulate add sound absorption as well as insulation.
- Damping mats aren't insulation and don't stop condensation on their own.
9. Common mistakes
- Expanding foam in cavities, which can bow panels and trap water.
- Glass fibre that gets wet and sags.
- Gaps between boards and around ribs, which become cold, wet spots.
- No vapour control, or a vapour barrier with untaped seams and holes.
- Blocking drain holes in door bottoms and sills.
- Relying on foil bubble wrap as "insulation".
- Unflued gas heaters, which add water and carbon monoxide.
10. Rules worth knowing
- UK: to reregister a van as a "motor caravan" with the DVLA, the vehicle must look like a motor caravan from outside (since 2019, external features such as windows, an awning rail and graphics are assessed). Insulation itself isn't assessed, but it affects comfort and condensation.
- Fire: use materials with a good fire rating where possible, keep insulation away from heater exhausts and flues, and fit smoke and CO alarms.
- Tiny houses and buildings must meet the energy efficiency rules of the local building code where they're classed as buildings; see the off-grid cabin guide.
11. Frequently asked questions
What is the best insulation for a campervan?
For the best warmth per millimetre, PIR board on flat areas and the roof, with closed-cell foam on ribs and curves, and polyester or wool in deep cavities. Closed-cell foam alone is easy and moisture-proof but costs more for the same warmth.
Do I need a vapour barrier in a van?
Yes, on the warm (inside) face of the insulation, with all joints taped. Foil-faced PIR and closed-cell foam act as one when joints are sealed. Never leave an air gap where moist air can reach the cold metal.
How do I stop condensation in my campervan?
Insulate fully including the ribs, fit a vapour control layer, ventilate with a roof fan, cook with lids on, use a vented diesel heater rather than an unflued gas heater, and use insulated window covers.
Is bubble foil good insulation?
On its own, no: its insulation value is very low. It only helps as a reflective layer with an air gap, in addition to proper insulation.
12. Sources
- Car Insulation UK, how to stop condensation in a campervan: carinsulation.co.uk
- Car Insulation UK, how to install a vapour barrier in your van: carinsulation.co.uk
- Two Wandering Soles, van insulation DIY guide: twowanderingsoles.com
- Build a Campervan, insulation: buildacampervan.com
New to some of the terms? See the glossary. Not sure where to start? Try start here.