Home › Guides › Charge controllers

Solar charge controllers: PWM vs MPPT, sizing and settings

How PWM and MPPT controllers work, when each makes sense, sizing for current and maximum PV voltage, series and parallel panels, charge settings for lead-acid and lithium, installation and fusing, and troubleshooting.

By Michael Johnson · Updated 17 November 2026 · How we check our guides

The solar charge controller sits between your panels and your battery and decides how much of the sun's energy actually ends up stored. Choosing PWM when you needed MPPT, picking one too small, or leaving it on the wrong battery setting are among the most common reasons a solar system underperforms or kills batteries early. This guide covers how PWM and MPPT work, when each makes sense, sizing for current and voltage, wiring panels in series or parallel, settings for each battery type, and troubleshooting.

Size it in numbers: the charge controller calculator checks current and voltage, the MPPT string voltage calculator checks cold-weather voltage, and the series/parallel calculator works out the wiring.

1. What a charge controller does

PWM vs MPPT: where the energy goes Example: 200 W panel (Vmp 20 V, Imp 10 A) charging a 12 V battery at 13 V. PWM controller MPPT controller Panel 200 W, 20 V PWM Battery 13 V 10 A Panel pulled down to 13 V 10 A × 13 V ≈ 130 W the extra 7 V is wasted 130 W into the battery Panel 200 W, 20 V MPPT Battery 13 V 14.6 A Panel held at 20 V (max power) DC-DC converter turns volts into amps 200 W × 95% ≈ 190 W 190 W into the battery
A PWM controller connects the panel straight to the battery; an MPPT controller converts the panel's higher voltage into extra charging current.

2. PWM controllers

3. MPPT controllers

PWM output ≈ panel current × battery voltage MPPT output ≈ panel power × converter efficiency (≈ 95–98%)

Example: a 200 W "12 V" panel (Vmp 20 V, Imp 10 A) charging a battery at 13 V gives about 130 W through PWM (10 A × 13 V) but about 190 W through MPPT.

4. PWM or MPPT?

SituationChoose
Single small 12 V panel (up to about 100–150 W), short cables, tight budgetPWM is fine
Anything over about 200 WMPPT
House panels (60/72-cell) or panels in seriesMPPT (required)
Long cable from panels to batteryMPPT, with panels in series
Cold climate or winter useMPPT (bigger gain when cold)
Lithium batteryEither, but it must have a lithium profile; MPPT preferred

5. Sizing: current and voltage

6. Series, parallel and shading

SeriesParallel
VoltageAdds upStays the same
CurrentStays the sameAdds up
CablesThinner; less lossThicker; more loss at low voltage
ShadingShade on one panel drags the string down (bypass diodes help)Each panel works independently
ControllerMPPT onlyPWM or MPPT
FusingNo string fuse needed for one stringFuse each string when three or more are in parallel

On vans, where roof panels get partial shade, series-parallel (2S2P) or one controller per panel can harvest more. Don't mix panels of very different specifications in the same string.

7. Settings for each battery type

Battery (12 V)AbsorptionFloatEqualiseTemperature compensation
Flooded lead-acid14.4–14.8 V13.2–13.5 VOccasionally, 15.5–16 VYes
AGM14.4–14.7 V13.5–13.8 VNo (unless the maker allows)Yes
Gel14.1–14.4 V13.5–13.8 VNoYes
LiFePO414.2–14.6 V (short)13.4–13.6 V or offNeverNo (but block charging below 0 °C)

Double for 24 V and multiply by four for 48 V. Always follow your battery maker's figures. See the battery charging voltage calculator.

8. Installation and fusing

  1. Connect the battery first so the controller detects the system voltage, then the panels. Disconnect in the reverse order.
  2. Fit a fuse or breaker between controller and battery, close to the battery, rated about 1.25 × the controller's output current.
  3. Fit a DC isolator (and string fuses where needed) on the panel side.
  4. Keep the controller close to the battery (short, thick cables) and mount it vertically with space for cooling.
  5. Fit the battery temperature sensor if the controller has one (for lead-acid), and use a battery voltage sense lead if offered.
  6. Size cables with the DC cable size calculator.
Solar panels, breaker, MPPT controller, battery and loadsSolar panelsPV breakerMPPTcharge controllerPanel side: live in daylightFuse near batteryBatteryBusbars, inverterand fused loadsConnect the battery to the controller first, then the panels.PositiveNegativeFuse or breaker
A simple off-grid solar layout: a DC breaker lets you isolate the panels; the controller's battery cable has a fuse close to the battery; loads and the inverter are fed from the battery through their own fuses.

9. Troubleshooting

SymptomLikely causeCheck
No charging in the morningPV voltage not yet above battery + start thresholdNormal; wait for more light
Low output on a sunny dayShade, dirty panels, wrong angle, PWM with high-voltage panels, controller at its current limitMeasure PV voltage and current at the controller
Battery never reaches fullAbsorption voltage or time too low, loads running all day, undersized arrayCheck settings and daily yield
Controller shows error or overvoltagePV voltage above the maximum in cold weatherReduce panels in series
Lithium battery cuts out when chargingVoltage set too high, or charging below 0 °CUse the lithium profile

For a step-by-step method, see the fault-finding guide.

10. Frequently asked questions

Is MPPT better than PWM?

For most systems, yes: an MPPT controller harvests 10–30% more energy and lets you use higher-voltage panels and thinner cables. PWM is fine for a single small 12 V panel on a short cable.

What size charge controller do I need?

For MPPT: panel watts ÷ battery voltage × 1.25. 400 W on a 12 V battery needs about a 40 A controller, and its maximum PV voltage must exceed the panels' cold-weather open-circuit voltage.

Can I use a house solar panel with a 12V battery?

Yes, with an MPPT controller rated for the panel's voltage. A PWM controller would waste most of the energy.

Should I connect the battery or panels first?

Battery first, so the controller detects the system voltage; then the panels. Disconnect panels first.

11. Sources

  1. Victron Energy, which solar charge controller: PWM or MPPT: victronenergy.com
  2. Morningstar, grounding in off-grid solar systems: morningstarcorp.com

New to some of the terms? See the glossary. Not sure where to start? Try start here.