Home › Guides › Inverters

Inverters: choosing, sizing and wiring one safely

Everything about inverters for vans, boats, cabins and home backup: types, pure versus modified sine wave, sizing for continuous load, surge and idle draw, choosing 12, 24 or 48 V, low- versus high-frequency designs, inverter-chargers, DC wiring and fusing, earthing and RCDs, installation, troubleshooting and the standards in the UK, USA and Australia.

By Michael Johnson · Updated 17 November 2026 · How we check our guides

An inverter turns battery DC into mains-style AC so you can run ordinary appliances in a van, boat, cabin or during a power cut. Picking the wrong one, or wiring it badly, is the most common cause of flat batteries, tripping, buzzing appliances and melted cables in small off-grid systems. This guide explains the types, how to size one, how to wire the DC and AC sides safely, earthing and RCDs, and the standards that apply in the UK, USA and Australia.

Inverter output is as dangerous as the mains. 230 V or 120 V AC from an inverter can kill. Once it feeds fixed wiring in a building, caravan or boat, it's an electrical installation with rules about who can do the work (section 10). The DC side carries very high currents: an unfused short across a lithium battery can melt cable and start a fire in seconds.

1. Types of inverter

TypeWhat it doesTypical use
Plug-in / cigarette-socketSmall (100–300 W) inverter on a 12 V socketCharging laptops in a car
Stand-alone inverterBattery to AC onlyVans, boats, cabins with separate chargers
Inverter-chargerInverter plus mains battery charger and automatic transfer switchVans, boats and caravans with hook-up or shore power; home backup
Off-grid hybrid / all-in-oneInverter-charger plus solar MPPT controller(s)Cabins and sheds; neat, but one failure takes out everything
Grid-tie / grid-hybridSynchronises with and exports to the gridHome solar; covered in the grid-tied solar guide
Portable power stationBattery, charger and inverter in one boxSee the portable power station guide

2. Pure sine vs modified sine

Wiring an inverter: short, thick DC and protected AC Fuse at the battery, an isolator, the shortest possible cables, then RCD-protected AC outlets. Battery 12/24/48 V LiFePO4 + BMS Class T / MRBF fuse ≤ 300 mm Isolator rated for current Inverter pure sine wave or inverter-charger negative (often via shunt) DC: as short as possible, sized for the fuse RCD / RCBO 30 mA Sockets Fixed loads Earth / chassis bond (to maker's rules) Neutral–earth bond inside the inverter (or via its relay) so the RCD can work Pure sine Modified sine (stepped) Motors, fridges, chargers and audio run hotter or noisier on modified sine.
A safe inverter installation, and the difference between pure and modified sine wave output.

Pure sine wave inverters make a smooth AC wave like the grid. Modified sine wave (really a stepped square wave) inverters are cheaper but cause problems:

Pure sine inverters are now cheap enough that a modified sine inverter only makes sense for a simple heater or tool. For anything permanent, buy pure sine.

3. Sizing: continuous, surge and idle draw

  1. Continuous rating: add up everything that might run at once. Choose an inverter rated at least 20–25% above that.
  2. Surge rating: motors and compressors need 2–7 times their running power for a fraction of a second to start. The inverter's surge rating (often 2× continuous for a few seconds) must cover the biggest start-up while other loads run.
  3. Idle (no-load) draw: an inverter left on with nothing running still uses power: 5–15 W for a small unit, 20–50 W for a large low-frequency one. 30 W over 24 hours is 720 Wh, a big share of a small battery. Use a power-saving (search) mode or switch it off when not needed.
UseTypical loadsInverter size
Laptop, phone, camera charging50–150 W300–500 W
Van with coffee machine or hair dryer1,000–1,500 W1,600–2,000 W
Van or boat with induction hob or microwave1,500–2,500 W2,500–3,000 W at 24 V or a large 12 V unit
Cabin with fridge, pump, tools1,500–3,000 W; surges 5,000 W+3,000–5,000 W low-frequency, 24 or 48 V
Home backup, essential circuits1,000–3,000 W3,000–5,000 W inverter-charger

Find appliance figures in the appliance wattage chart and size the inverter with the inverter size calculator.

Battery current

Battery current (A) ≈ AC watts ÷ efficiency (0.9) ÷ battery voltage 2,000 W at 12 V ≈ 2,000 ÷ 0.9 ÷ 12 ≈ 185 A (more as the battery voltage sags)

Your battery must be able to supply that current: check its BMS continuous rating. A 100 Ah lithium battery with a 100 A BMS can't run a 2,000 W inverter at full power. Work it out with the inverter battery current calculator.

4. 12, 24 or 48 V?

Inverter sizeSuggested battery voltageCurrent at full load
Up to 1,500 W12 VUp to about 140 A
1,500–3,000 W24 V (12 V possible with very short, heavy cables)70–140 A at 24 V
3,000 W and above48 VUp to 70 A at 48 V for 3 kW

In vehicles, 12 V is convenient because everything else is 12 V. A 24 V or 48 V house battery with a DC-DC converter for 12 V loads is the usual answer for large inverters.

5. Low-frequency vs high-frequency

Low-frequency (transformer)High-frequency (switch-mode)
WeightHeavy (a 3 kW unit can weigh 20–30 kg)Light (3–8 kg for 3 kW)
Surge capabilityHigh: often 3× for several secondsModerate: often 2× for a fraction of a second to a few seconds
Idle drawHigherLower
Best forPumps, compressors, workshop tools, cabinsVans, boats and electronics

6. Inverter-chargers and transfer switching

An inverter-charger has an internal transfer relay. When shore power, hook-up or a generator is connected, it passes that supply through to your AC circuits and charges the battery. When the supply disappears, it switches to inverting in about 10–20 ms, fast enough that most computers don't notice.

Never connect an inverter's output to a building's wiring through a plug (a "suicide lead"). It can back-feed the grid and electrocute someone. Use a proper changeover switch or a listed transfer switch; see the home backup power guide.

7. Wiring the DC side

8. The AC side, earthing and RCDs

An inverter's output is a new, separate supply. For an RCD to work, there must be a path for fault current: in most installations that means neutral connected to earth (bonded) at the inverter, and the inverter's earth connected to the vehicle chassis, boat earth or an earth electrode.

9. Installation: location, ventilation, interference

10. Rules and standards by country

United Kingdom

United States

Australia

11. Troubleshooting

SymptomLikely causeFix
Low-voltage alarm when a big load startsVoltage drop in thin or long DC cables, or a weak batteryThicker, shorter cables; check connections are tight; test the battery
Inverter shuts off; lithium battery goes deadBMS over-current tripCheck the BMS continuous and surge rating; add a second battery in parallel
Overload on motor startStart-up surge exceeds the inverter's surge ratingSoft-starter, larger or low-frequency inverter
Hot DC terminals or lugsLoose or poorly crimped lugRe-crimp properly and torque to the maker's figure
RCD won't trip on testNo neutral–earth bond on the inverter outputCheck the inverter's earthing instructions
Buzzing appliancesModified sine wave outputUse a pure sine inverter
Flat battery overnight with nothing onInverter idle drawUse search/eco mode or switch it off

12. Frequently asked questions

What size inverter do I need?

Add up everything that could run at once and add 20–25%. Check the inverter's surge rating covers the biggest motor's start-up. For most vans 1,500–2,000 W is plenty; for a kettle or induction hob you need 2,500–3,000 W.

Do I need a pure sine wave inverter?

For almost everything, yes. Modified sine inverters can damage or upset motors, chargers, medical devices and electronics. They're only suitable for simple resistive loads like heaters.

How many batteries do I need for a 2000 W inverter?

At 12 V, a 2,000 W inverter draws about 185 A at full load, so the battery bank must be able to deliver that continuously, usually two 100 A-BMS lithium batteries in parallel or one rated 200 A. How many Ah you need depends on how long you run it.

What size fuse for an inverter?

About 1.25 times the battery current at full load, rounded up: about 300 A for 2,000 W at 12 V, or 150 A at 24 V. Use a Class T or MRBF fuse near the battery.

Does an inverter need to be earthed?

Usually yes: the inverter's earth goes to the vehicle chassis, boat earth or an earth electrode, and neutral is bonded to earth (inside the inverter or by its relay) so RCDs work. Always follow the maker's instructions.

Can I plug an inverter into my house wiring in a power cut?

Not through a plug. It can back-feed the grid and is illegal and dangerous. Use an approved changeover or transfer switch fitted by an electrician.

13. Sources

  1. IET, electrical installations in caravan parks, caravans and motor caravans: theiet.org
  2. Intertek, UL 458 power converters/inverters for land vehicles and marine craft: intertek.com
  3. Panbo, ABYC updated battery and electrical standards (E-11 and E-13, 2025): panbo.com
  4. Caravan Industry Association WA, latest electrical standards for RVs (AS/NZS 3001:2022): caravanwa.com.au
  5. Standards Australia, AS/NZS 4509.1 stand-alone power systems: standards.org.au
  6. Maritime Safety Queensland, electrical standards and licences for boats: msq.qld.gov.au

New to some of the terms? See the glossary. Not sure where to start? Try start here.